Skip to main content
Siemens 3VA2340-7HL32-0CL0 — Molded Case Circuit Breakers (MCCB)

3VA2340-7HL32-0CL0 SENTRON MCCB, 400 A, 330 kA at 240 V

MPN3VA2340-7HL32-0CL0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2340-7HL32-0CL0, 3-pole, 400 A continuous, 330 kA breaking capacity at 240 V, line protection, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-7HL32-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2340-7HL32-0CL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-7HL32-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-7HL32-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-7HL32-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2340-7HL32-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-7HL32-0CL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Its interrupting capacity reaches 330 kA at 240 V AC and 242 kA at 415/440 V, dropping to 7.5 kA at 690 V — the high 240 V figure tells you this breaker is built for low-voltage high-fault points like transformer secondaries or large motor control centers. Thermal derating is published: full 400 A up to 50 °C, then 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C — useful when the breaker sits in a warm enclosure near other heat sources.

The base switch is order code 3VA2340-7HL32-0AA0.

That depth is shallow enough to fit most standard distribution panels without a deep can — check your gland plate clearance for the rear terminals.

Environmental limits

Frequently asked questions

Where can I buy 3VA2340-7HL32-0CL0 and how do I get a price?

We source this part to order against an RFQ. Submit a request and we'll confirm availability and current pricing at quote time.

Will 3VA2340-7HL32-0CL0 drop into a panel that was specified around 3VA2116-5HL32-0AK0 without rewiring?

Both are 3-pole SENTRON MCCBs with similar auxiliary switch options, but the 3VA2340 is a higher-frame (400 A vs 160 A) and physically larger — it will not fit the same footprint without panel modifications.

What is 3VA2340-7HL32-0CL0's listed depth?

110 mm.

What is 3VA2340-7HL32-0CL0's listed width?

138 mm.

What compliance documentation does this brand provide for 3VA2340-7HL32-0CL0?

The SENTRON series typically carries UL, IEC, and CE certifications; specific documentation for this order code should be requested at quote time.

MPN
3VA2340-7HL32-0CL0