Siemens 3VA2340-7HN32-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-7HN32-0DL0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2340-7HN32-0DL0

Siemens SENTRON 3VA2340-7HN32-0DL0, molded case circuit breaker, 3-pole, 400 A rated continuous current, 330 kA breaking capacity at 240 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2340-7HN32-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-7HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2340-7HN32-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.98.5 W
3VA2340-7HN32-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2340-7HN32-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-7HN32-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2340-7HN32-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-7HN32-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Siemens 3VA2340-7HN32-0DL0 — 400 A SENTRON MCCB, 3-Pole, Line Protection

It carries a 330 kA breaking capacity at 240 V, stepping down to 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V — the high interrupting ratings at lower voltages suit it for fault-current-heavy service-entrance or main-breaker positions where upstream coordination demands full-rated SCCR. Thermal derating begins above 55 °C: it holds 400 A through 50 °C, then drops to 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. A trip indicator is present.

Integration Notes

The 3VA2340-7HN32-0DL0 mounts into a standard SENTRON panel or enclosure footprint. The UVR coil requires a separate control voltage — verify the undervoltage release rating against your control circuit before wiring. The auxiliary switch set (2+1+1) provides status feedback for PLC or SCADA monitoring without an add-on module.

Frequently asked questions

How do I get current pricing and availability for 3VA2340-7HN32-0DL0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our sourcing network.

What are the key ratings for 3VA2340-7HN32-0DL0?

Rated 400 A continuous at 40 °C, 3-pole, with a breaking capacity of 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 7.5 kA at 690 V.

What is the depth of 3VA2340-7HN32-0DL0?

The depth is 110 mm (4.33 in).

What auxiliary switches does 3VA2340-7HN32-0DL0 include?

It includes two auxiliary switches, one trip alarm switch, and one electrical alarm switch (HQ configuration), plus an undervoltage release.

MPN