Siemens 3VA2340-7HN32-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-7HN32-0JC0 SENTRON MCCB, 400 A, 3-Pole, 330

MPN3VA2340-7HN32-0JC0

Siemens SENTRON 3VA2340-7HN32-0JC0, molded case circuit breaker, 3-pole, 400 A continuous current, 330 kA breaking capacity at 240 VAC, with shunt trip and 2 auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2340-7HN32-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2340-7HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2340-7HN32-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W

Protection & Trip Unit

3VA2340-7HN32-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2340-7HN32-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2340-7HN32-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2340-7HN32-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2340-7HN32-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Siemens SENTRON 3VA2340-7HN32-0JC0 — 400 A MCCB with Shunt Trip

The Siemens SENTRON 3VA2340-7HN32-0JC0 is a 3-pole molded case circuit breaker (MCCB) rated for 400 A continuous current at 40 °C ambient, with a maximum breaking capacity of 330 kA at 240 VAC. It carries a shunt trip release (STL) and two auxiliary switches (HQ) factory-installed, making it suited for remote-trip and status-monitoring applications in distribution panels.

Breaking Capacity and Selectivity Planning

The 330 kA at 240 VAC is the highest short-circuit rating on this frame size — per the datasheet, it drops to 242 kA at 415 VAC and 187 kA at 500 VAC, then to 7.5 kA at 690 VAC. For a site engineer coordinating with upstream protective devices, the 400 A continuous rating holds flat from 40 °C through 50 °C (no derating needed), then steps down to 385 A at 55 °C and 340 A at 70 °C. That thermal curve governs the actual ampacity in a sealed enclosure.

Panel Integration and Dimensions

The 3VA2340-7HN32-0JC0 measures 248 mm high by 138 mm wide by 110 mm deep — a standard SENTRON 3VA frame footprint. It mounts on a DIN rail or directly to a backplate via the four corner slots. The shunt trip (STL) operates on a separate control voltage; verify polarity and coil rating against the panel's control transformer before wiring. The two auxiliary switches (HQ) provide Form C contacts for status feedback to a PLC or annunciator.

Environmental and Storage Limits

Storage temperature range is -40 °C to 80 °C; operating ambient is -25 °C to 70 °C. Maximum power loss at rated current is 96 W — factor that into enclosure thermal calculations for a multi-breaker lineup.

Frequently asked questions

Where can I buy 3VA2340-7HN32-0JC0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time, not listed here.

What is 3VA2340-7HN32-0JC0's breaking capacity at 240 V?

The breaking capacity is 330 kA at 240 VAC, dropping to 242 kA at 415 VAC and 187 kA at 500 VAC.

What auxiliary switches and releases are included?

The breaker ships with two auxiliary switches (HQ design) and a shunt trip release (STL) factory-installed.

MPN
3VA2340-7HN32-0JC0