Siemens 3VA2440-5HL32-0AJ0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2440-5HL32-0AJ0

Siemens SENTRON 3VA2440-5HL32-0AJ0, molded case circuit breaker, 3-pole, 400 A at 40 °C, ETU320 electronic trip unit, line protection, 187 kA at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HL32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2440-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2440-5HL32-0AJ0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C384 A
Current at 60 °C376 A
Current at 65 °C368 A
Current at 70 °C360 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.63.5 W
3VA2440-5HL32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA2440-5HL32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HL32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2440-5HL32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HL32-0AJ0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

It carries 400 A continuously at 40 °C ambient, with the same rating holding at 45 °C and 50 °C — no derating needed until you cross 55 °C, where it drops to 384 A. The interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V, giving you selectivity headroom across common distribution voltages.

The 3VA2440-5HL32-0AJ0 measures 248 mm high by 138 mm wide by 110 mm deep. The auxiliary contact version (2 switches + 1 trip alarm) is already populated on the basic switch 3VA2440-5HL32-0AA0. If your BOM calls for separate alarm or status feedback, this variant saves an add-on module slot.

Frequently asked questions

How do I get current pricing and availability for 3VA2440-5HL32-0AJ0?

Submit an RFQ through this listing. We source through independent distribution and confirm price and stock at quote time — no automated figures here.

What is 3VA2440-5HL32-0AJ0's interrupting capacity at 240 V?

187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V.

What trip unit does this MCCB use?

The ETU320 electronic trip unit, designed for line protection with no undervoltage release, ground-fault monitoring, or communication function.

What auxiliary contacts come with 3VA2440-5HL32-0AJ0?

It ships with 2 auxiliary switches plus 1 trip alarm switch (HP version), pre-populated on the basic switch 3VA2440-5HL32-0AA0.