Skip to main content
Siemens 3VA2440-5HL32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5HL32-0BA0 SENTRON MCCB, 400A, 3-Pole, 187kA

MPN3VA2440-5HL32-0BA0

Siemens SENTRON 3VA2440-5HL32-0BA0, Molded case circuit breaker, 3-pole, 400 A, line protection, with undervoltage release, interrupting capacity 187 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HL32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-5HL32-0AA0
3VA2440-5HL32-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.66 W
3VA2440-5HL32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2440-5HL32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HL32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2440-5HL32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HL32-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2440-5HL32-0BA0 is a 3-pole molded case circuit breaker rated for line protection, carrying a continuous current of 400 A across the full ambient range from 40 °C to 70 °C — no derating needed in a warm enclosure. Its interrupting capacity hits 187 kA at 240 V AC, 121 kA at 415/440 V, 75.6 kA at 500 V, and 9 kA at 690 V, giving you selectivity headroom well beyond typical 400 A service entrance or feeder duty.

The 400 A rating is thermally stable: the breaker carries 400 A continuously at any ambient from 40 °C up to 70 °C, which is unusual — many MCCBs start derating above 40 °C. That means you can mount it in a crowded, warm panel without losing ampacity. The interrupting ratings span the common industrial voltages: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V.

Integration — Panel Fit & Wiring

Dimensions are 248 mm height, 138 mm width, 110 mm depth — a standard SENTRON 3VA frame size that fits the same mounting footprint as other 3VA2 breakers. The 110 mm depth includes the handle and terminals, so check gland-plate clearance if the panel door is shallow. The auxiliary release is an undervoltage release (UVR) — wired separately from the main power path. It's a shunt-trip style that opens the breaker on loss of control voltage.

Frequently asked questions

How do I get current pricing and availability for 3VA2440-5HL32-0BA0?

Submit an RFQ through this listing. Pricing and stock levels are confirmed at quote time — we source through independent distribution and can provide current market pricing and lead time on request.

What is the interrupting capacity of this breaker at 415 V?

121 kA at 415 V AC. That's the same rating as at 440 V, which covers the common 400/415 V industrial supply. At 240 V it's 187 kA, at 500 V it's 75.6 kA, and at 690 V it's 9 kA.

Does this breaker require derating at high ambient temperatures?

No derating needed up to 70 °C. The 3VA2440-5HL32-0BA0 carries its full 400 A rating continuously at any ambient from 40 °C through 70 °C.

What compliance documentation is available for this MCCB?

The Siemens SENTRON 3VA series carries IEC/EN 60947-2 certification. Specific UL/CSA listings, RoHS, and REACH declarations are available from Siemens upon request — this listing does not include those documents directly.