MPN3VA2440-5HL32-0CA0

Siemens SENTRON 3VA2440-5HL32-0CA0, molded case circuit breaker, 3-pole, 400 A rated continuous current, line protection, ETU320 overcurrent release, undervoltage release, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HL32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2440-5HL32-0AA0
3VA2440-5HL32-0CA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C384 A
Current at 60 °C376 A
Current at 65 °C368 A
Current at 70 °C360 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.66 W
3VA2440-5HL32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2440-5HL32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HL32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2440-5HL32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HL32-0CA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

Rated continuous current Iu is 400 A, and the breaker carries a 3-pole configuration (three-phase). The overcurrent release is an ETU320 electronic trip unit, which gives adjustable pickup and time-delay settings for coordination. That is useful for emergency-stop circuits or undervoltage protection on motor feeders.

This MCCB's interrupting rating depends on the system voltage you feed it. At 240 V it can clear 187 kA; at 415 V or 440 V it handles 121 kA; at 500 V it drops to 75.6 kA; at 690 V it still holds 17 kA. The 17 kA at 690 V covers most 690 V motor-control applications.

Thermal derating — how hot can your panel get?

At 55 °C it derates to 384 A, at 60 °C to 376 A, at 65 °C to 368 A, and at 70 °C to 360 A. Factor it into your thermal calculation when grouping multiple breakers.

Depth of 110 mm means it clears typical enclosure back-panel clearance.

Frequently asked questions

What is 3VA2440-5HL32-0CA0's listed depth?

The depth is 110 mm, with a width of 138 mm and height of 248 mm.