Siemens 3VA2440-5HL32-0CC0 SENTRON MCCB, 400 A, 3-Pole, ETU3

MPN3VA2440-5HL32-0CC0

Siemens SENTRON 3VA2440-5HL32-0CC0, molded case circuit breaker, 3-pole, 400 A at 40 °C, ETU320 trip unit, line protection, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HL32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2440-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2440-5HL32-0CC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C384 A
Current at 60 °C376 A
Current at 65 °C368 A
Current at 70 °C360 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.66 W
3VA2440-5HL32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA2440-5HL32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HL32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2440-5HL32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HL32-0CC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The Siemens SENTRON 3VA2440-5HL32-0CC0 is a 3-pole molded case circuit breaker rated 400 A at 40 °C, with an ETU320 electronic trip unit configured for line protection.

Rated current holds flat at 400 A from 40 °C up to 50 °C, then drops to 384 A at 55 °C, 376 A at 60 °C, 368 A at 65 °C, and 360 A at 70 °C. If the panel ambient sits at 55 °C, the breaker is good for 384 A continuous — no margin games. Maximum power loss is 66 W, which matters for ventilation in a sealed enclosure.

Interrupting capacity by voltage

At 240 V the breaker clears 187 kA; at 415 V and 440 V it clears 121 kA; at 500 V it clears 75.6 kA; at 690 V it clears 17 kA.

Physical footprint

That depth is the body only — add clearance for the UVR coil and auxiliary wiring.

Frequently asked questions

Who supplies 3VA2440-5HL32-0CC0 and how is it quoted for volume purchases?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 3VA2440-5HL32-0CC0's listed depth (110 mm) on this component line?

The depth is 110 mm. That is the body depth; add clearance for the undervoltage release and auxiliary wiring.

What is 3VA2440-5HL32-0CC0's listed width (138 mm) on this component line?

The width is 138 mm, which is the standard 3-pole MCCB footprint.

MPN
3VA2440-5HL32-0CC0