Skip to main content
Siemens 3VA2440-5HL32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5HL32-0HH0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2440-5HL32-0HH0

Siemens SENTRON 3VA2440-5HL32-0HH0, molded case circuit breaker, 3-pole, 400 A, adjustable thermal-magnetic trip 600–4800 A, breaking capacities 187 kA at 240 V / 121 kA at 415 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HL32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2440-5HL32-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W
3VA2440-5HL32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2440-5HL32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HL32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2440-5HL32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HL32-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

400 A MCCB with full-temperature rating and adjustable trip

The Siemens SENTRON 3VA2440-5HL32-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying its full 400 A continuously from 40 °C through 70 °C — no derating curve to chase across the ambient range of a warm panel. The thermal-magnetic trip unit is adjustable between 600 A and 4800 A, so one breaker body covers a wide range of downstream loads or transformer inrush profiles; set it at commissioning, not at ordering. Breaking capacity reaches 187 kA at 240 V and holds 121 kA at 415 V and 440 V, dropping to 75.6 kA at 500 V and 9 kA at 690 V — the high 240 V figure suits large LV transformer secondaries or bus-tie positions where fault current is severe.

Panel fit and auxiliary configuration

Dimensions 248 mm high × 138 mm wide × 110 mm deep (9.76 × 5.43 × 4.33 in) — standard 3-pole MCCB footprint for Siemens SENTRON 3VA frames; verify bus-bar centers and mounting hole pattern against the existing panel layout. The basic switch variant is 3VA2440-5HL32-0AA0; this order code adds the shunt trip and auxiliary switches at the factory, saving panel-build labor.

Frequently asked questions

Does it include auxiliary switches or a shunt trip?

Yes, factory-fitted with a shunt trip release (STL) and an auxiliary switch block with 2 auxiliary switches plus 1 trip alarm switch (HQ).

MPN
3VA2440-5HL32-0HH0