Skip to main content
Siemens 3VA2440-5HN32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5HN32-0AC0 SENTRON MCCB, 400 A, 4800 A frame

MPN3VA2440-5HN32-0AC0

Siemens SENTRON molded case circuit breaker, 3VA2440-5HN32-0AC0, 3-pole, 400 A at 40 °C, 4800 A frame, 187 kA interrupting at 240 V, line protection, 2 auxiliary switches HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2440-5HN32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2440-5HN32-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W

Protection & Trip Unit

3VA2440-5HN32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2440-5HN32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2440-5HN32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2440-5HN32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2440-5HN32-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB delivers

The Siemens 3VA2440-5HN32-0AC0 is a SENTRON molded case circuit breaker rated for line protection, built on a 4800 A frame and delivering 400 A continuous at 40 °C — no derating needed up to 70 °C, which simplifies panel thermal budgeting when you're packing breakers close together. Interrupting capacity hits 187 kA at 240 V and still holds 121 kA at 415 V, so it handles high-fault utility feeds or transformer secondaries without cascading upstream. The 3-pole design includes two built-in auxiliary switches (HQ type) for remote status feedback — no separate aux kit to order and fit.

Panel fit and environment

At 248 mm tall, 138 mm wide, and 110 mm deep, this MCCB fits standard distribution panel cutouts and leaves room for gland plates and cable bending radius on the line side. Rated for operation from -25 °C to 70 °C, with storage down to -40 °C — fine for unheated warehouses or outdoor enclosures in temperate climates. Maximum power loss of 63.5 W means the breaker dissipates heat into the enclosure; factor that into your panel cooling calculation if you're grouping several high-frame units.

Frequently asked questions

Does this breaker come with auxiliary contacts?

Yes, it includes two built-in auxiliary switches (HQ type) for remote status indication — no separate accessory required.

MPN
3VA2440-5HN32-0AC0