Skip to main content
Siemens 3VA2440-5HN32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5HN32-0AH0 SENTRON MCCB, 400 A, 3-Pole, 4800

MPN3VA2440-5HN32-0AH0

Siemens SENTRON 3VA2440-5HN32-0AH0, molded case circuit breaker, 3-pole, 400 A rated current, 4800 A frame, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HN32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2440-5HN32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W
3VA2440-5HN32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2440-5HN32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HN32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2440-5HN32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HN32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB carries

The Siemens 3VA2440-5HN32-0AH0 is a SENTRON molded case circuit breaker sized for a 400 A continuous load on a 4800 A frame, 3-pole, designed for line protection in distribution panels. Rated current holds steady at 400 A across the full operating temperature range from 40 °C to 70 °C — no derating needed for warm enclosures or summer ambient conditions. Interrupting capacity varies by system voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V. That 187 kA at 240 V covers high-fault industrial services and transformer secondaries. Max power loss is 63.5 W — thermal dissipation to account for in enclosure sizing if the panel is tightly packed.

Panel fit and integration

Mounts on a DIN rail or bolts into a panel base. Dimensions: 248 mm high, 138 mm wide, 110 mm deep. The 138 mm width is the standard 3-pole MCCB footprint — fits existing SENTRON or third-party busbar systems without re-drilling. Comes with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration) factory-fitted — no need to order separate signal contacts for status feedback to a PLC or remote annunciator. No undervoltage release, no ground-fault monitoring, no communication module on this variant. If those are needed, the 3VA family has other order codes with those options built in.

MPN
3VA2440-5HN32-0AH0