Siemens 3VA2440-5HN32-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5HN32-0DC0 SENTRON MCCB, 400 A, 4800 A frame

MPN3VA2440-5HN32-0DC0

Siemens SENTRON 3VA2440-5HN32-0DC0, molded case circuit breaker, 3-pole, 400 A continuous, 4800 A frame, 187 kA at 240 V, undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2440-5HN32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2440-5HN32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.66 W

Protection & Trip Unit

3VA2440-5HN32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2440-5HN32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2440-5HN32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2440-5HN32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2440-5HN32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB carries and where it fits

The Siemens 3VA2440-5HN32-0DC0 is a 3-pole SENTRON molded case circuit breaker sized for a 4800 A frame with a continuous current rating of 400 A across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling. Breaking capacity lands at 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V. That SCCR headroom covers most industrial service-entrance and feeder applications where fault currents run high, particularly on 480 V and 600 V class systems. The unit includes an undervoltage release (UVR) and two HQ auxiliary switches. Line protection design, no ground-fault monitoring, no communication module.

Integration dimensions

Footprint: 138 mm wide, 248 mm tall, 110 mm deep. The 110 mm depth is the dimension from the mounting surface to the front of the breaker — relevant when planning gland-plate clearance or enclosure depth. Standard DIN-rail or panel-mount installation per SENTRON 3VA family practice.

Power loss and thermal budget

Maximum power loss is 66 W. In a sealed enclosure that figure drives the internal temperature rise; account for it in the thermal budget alongside the 70 °C maximum operating ambient.

Frequently asked questions

Where can I buy 3VA2440-5HN32-0DC0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of 3VA2440-5HN32-0DC0?

3-pole, 4800 A frame, 400 A continuous current (no derating from 40 °C to 70 °C), breaking capacity of 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V. Includes undervoltage release and two HQ auxiliary switches.

Does 3VA2440-5HN32-0DC0 have an undervoltage release?

Yes, it includes an undervoltage release (UVR) as the auxiliary release type.

MPN
3VA2440-5HN32-0DC0