Skip to main content
Siemens 3VA2440-5HN32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5HN32-0JH0 SENTRON MCCB, 400 A, 187 kA

MPN3VA2440-5HN32-0JH0

Siemens SENTRON 3VA2440-5HN32-0JH0, molded case circuit breaker, 3-pole, 400 A rated continuous current Iu, 187 kA breaking capacity at 240 V, ETU350 electronic trip unit, line protection version.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HN32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2440-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2440-5HN32-0JH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C384 A
Current at 60 °C376 A
Current at 65 °C368 A
Current at 70 °C360 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.63.5 W
3VA2440-5HN32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2440-5HN32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HN32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2440-5HN32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HN32-0JH0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

400 A MCCB with 187 kA interrupting capacity

Its interrupting capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V — covering most industrial distribution voltages without needing a current-limiting upstream device.

Rated continuous current holds at 400 A up to 50 °C ambient, then derates to 384 A at 55 °C, 376 A at 60 °C, 368 A at 65 °C, and 360 A at 70 °C. For a panel running at 55 °C ambient, expect 384 A continuous capability — factor that into busbar and cable sizing.

Frequently asked questions

What compliance documentation does Siemens provide for this breaker?

The SENTRON 3VA series carries UL, CSA, and IEC certifications standard for molded case circuit breakers. Specific compliance documentation (RoHS, REACH, CE, UKCA, EAC) is available with the product documentation package.

MPN