Skip to main content
Siemens 3VA2440-5HN32-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5HN32-0KC0 SENTRON MCCB, 400 A, 3-Pole, Line

MPN3VA2440-5HN32-0KC0

Siemens SENTRON 3VA2440-5HN32-0KC0, molded case circuit breaker, 3-pole, 400 A rated continuous current, line protection version, ETU350 electronic trip unit, shunt trip release, 2 HQ auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5HN32-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2440-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2440-5HN32-0KC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C384 A
Current at 60 °C376 A
Current at 65 °C368 A
Current at 70 °C360 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.63.5 W
3VA2440-5HN32-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2440-5HN32-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5HN32-0KC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2440-5HN32-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5HN32-0KC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

Breaking capacity is the headline here: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V.

Thermal performance and derating

At 55 °C it derates to 384 A, at 60 °C to 376 A, at 65 °C to 368 A, and at 70 °C to 360 A. If your panel internal ambient runs above 50 °C — common in compact, high-density enclosures — you lose about 4 A per 5 °C rise. The maximum power loss is 63.5 W, which matters for enclosure thermal calculations when grouping several breakers. That 138 mm width for a 3-pole 400 A frame is standard for SENTRON 3VA2 — it fits the same mounting footprint as other breakers in the series, so panel cutouts and busbar layouts transfer.

Auxiliaries and release configuration

Two HQ auxiliary switches are fitted (form C, high-qualified for signal reliability). The basic switch assembly is order code 3VA2440-5HN32-0AA0; the integrated auxiliary trip module is 3VA9688-0BL33. Mechanical endurance is rated at 15,000 operations — typical for a 400 A frame in distribution duty where it cycles infrequently (a few times per year for maintenance isolation). No voltage trip indicator on this variant.

Frequently asked questions

Does 3VA2440-5HN32-0KC0 include a shunt trip?

Yes, it ships with a shunt trip (STL) release for remote tripping, plus two HQ auxiliary switches. No undervoltage release or communication module on this variant.

MPN
3VA2440-5HN32-0KC0