Siemens SENTRON 3VA2440-5JQ42-0AA0, molded case circuit breaker, 400 A, 4-pole, ETU560 electronic trip unit, 187 kA interrupting at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-5JQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2440-5JQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W
3VA2440-5JQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2440-5JQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-5JQ42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2440-5JQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-5JQ42-0AA0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.76 in
Width (in)7.24 in
Depth (in)4.33 in

Product details

Line protection MCCB with ETU560 — 400 A flat-rated across 70 °C

The Siemens SENTRON 3VA2440-5JQ42-0AA0 is a 4-pole molded case circuit breaker rated at 400 A continuous current, with the ETU560 electronic trip unit for line protection. It carries a full 400 A from 40 °C through 70 °C without derating — that's the entire operating temperature band, so no headroom calculation needed for a warm panel. Interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 9 kA at 690 V. The 187 kA figure at 240 V covers the highest fault-current scenarios on low-voltage distribution; the drop to 9 kA at 690 V still clears most industrial faults on that voltage class. Built-in communication function means it can talk to a BMS or SCADA system — no add-on module required.

Dimensions are 248 mm high, 184 mm wide, 110 mm deep. The 184 mm width is the 4-pole frame — verify busbar spacing and enclosure cutout before committing.

Frequently asked questions

What trip unit does the 3VA2440-5JQ42-0AA0 use?

The ETU560 electronic trip unit, designed for line protection. It supports communication functions for integration with monitoring systems.

MPN
3VA2440-5JQ42-0AA0