Siemens 3VA2440-5MN32-0BA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-5MN32-0BA0 SENTRON MCCB, 400 A, 187 kA

MPN3VA2440-5MN32-0BA0

Siemens SENTRON 3VA2440-5MN32-0BA0, molded case circuit breaker, 3-pole, 400 A, 187 kA interrupting at 240 V, motor protection design with undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2440-5MN32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-5MN32-0AA0

Ratings

3VA2440-5MN32-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.66 W

Protection & Trip Unit

3VA2440-5MN32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2440-5MN32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2440-5MN32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2440-5MN32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2440-5MN32-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

400 A MCCB with 187 kA interrupting capacity — motor protection variant

The Siemens SENTRON 3VA2440-5MN32-0BA0 is a 3-pole molded case circuit breaker rated for 400 A continuous current across the full ambient range from 40 °C through 70 °C — no derating needed up to that ceiling. Its interrupting capacity hits 187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V, so it handles high-fault utility feeds and large motor branch circuits without cascading upstream. This is the motor protection design variant, meaning the thermal-magnetic trip curve is shaped for motor starting inrush — it holds through the 4 to 17 second short-time delay window before clearing a bolted fault. Phase failure detection is built in, so a lost phase on the line side trips the breaker rather than letting the motor single-phase and burn. The breaker ships with an undervoltage release (UVR) fitted, which drops the trip mechanism when control voltage falls below the dropout threshold — standard for applications where a loss of control power must disconnect the load automatically. No auxiliary switch is included on this order code, so if you need remote status feedback, plan for a separate aux contact module.

Panel fit and integration

Dimensions are 110 mm deep, 138 mm wide, and 248 mm tall — a standard 3-pole MCCB footprint that drops into most SENTRON panelboard and enclosure cutouts without re-drilling. The 400 A frame uses bolted lug connections; verify busbar spacing and lug kit compatibility against your existing panel layout. Maximum power loss is 66 W, so factor that into enclosure thermal rise calculations — especially in a sealed stainless steel enclosure where natural convection is limited.

Environmental and storage limits

Operating temperature range is -25 °C to 70 °C; storage range extends from -40 °C to 80 °C. The storage limits govern handling and warehousing, not running conditions — the breaker can sit in a cold warehouse or hot truck without damage.

Frequently asked questions

Where can I buy 3VA2440-5MN32-0BA0 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What is the interrupting capacity of 3VA2440-5MN32-0BA0 at different voltages?

187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V.

Does 3VA2440-5MN32-0BA0 include an undervoltage release?

Yes, it ships with an undervoltage release (UVR) fitted as the auxiliary release.

What are the physical dimensions of 3VA2440-5MN32-0BA0?

110 mm deep, 138 mm wide, and 248 mm tall.

MPN
3VA2440-5MN32-0BA0