Siemens 3VA2440-6HL32-0AF0 SENTRON MCCB, 400A, 3-Pole, 4800A

MPN3VA2440-6HL32-0AF0

Siemens SENTRON 3VA2440-6HL32-0AF0, molded case circuit breaker, 3-pole, line protection, rated 400 A, interrupting capacity 242 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-6HL32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2440-6HL32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W
3VA2440-6HL32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2440-6HL32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-6HL32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2440-6HL32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-6HL32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Siemens 3VA2440-6HL32-0AF0 — SENTRON MCCB, 400 A, 3-Pole

It is a 3-pole unit designed for distribution and industrial feeder applications where high interrupting capacity is needed. Interrupting capacity is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 9 kA at 690 V — covering most low-voltage distribution scenarios with substantial fault-current headroom.

The basic switch version is 3VA2440-6HL32-0AA0.

The 3-pole design fits into existing SENTRON switchboard or distribution panel layouts. Maximum power loss is 63.5 W, which should be factored into enclosure thermal calculations.

Coordination and Selectivity

With a 4800 A frame and adjustable trip unit (minimum 600 A), this MCCB supports selective coordination with downstream breakers in a distribution hierarchy. The trip indicator aids troubleshooting during commissioning or fault events. No communication function or voltage trigger is included — this is a straightforward thermal-magnetic or electronic-trip line protection device without integrated metering or remote trip capability.

Frequently asked questions

Where can I buy the 3VA2440-6HL32-0AF0 and get a price?

This part is sourced to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing; stock and lead time are confirmed at quote time.

What are the key ratings of the 3VA2440-6HL32-0AF0?

It is a 3-pole, 400 A rated MCCB with a 4800 A frame. Interrupting capacity is 242 kA at 240 V, 187 kA at 415/440 V, 121 kA at 500 V, and 9 kA at 690 V. No derating needed from 40 °C to 70 °C.

What are the physical dimensions of the 3VA2440-6HL32-0AF0?

Height is 248 mm, width is 138 mm, and depth is 110 mm. It fits a standard MCCB panel cutout for 3-pole SENTRON breakers.

Does the 3VA2440-6HL32-0AF0 include auxiliary switches or a shunt trip?

It ships with one auxiliary switch and one trip alarm switch (HQ type). It does not include an undervoltage release, auxiliary release, or ground-fault monitoring.

MPN
3VA2440-6HL32-0AF0