Siemens 3VA2440-6HL32-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-6HL32-0DL0 SENTRON MCCB, 400 A, 242 kA at 24

MPN3VA2440-6HL32-0DL0

Siemens SENTRON 3VA2440-6HL32-0DL0, molded case circuit breaker, 3-pole, 400 A rated current (40-70 °C), 242 kA interrupting capacity at 240 V, line protection design with undervoltage release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2440-6HL32-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-6HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2440-6HL32-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V9 kA
Power loss, max.66 W

Protection & Trip Unit

3VA2440-6HL32-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2440-6HL32-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2440-6HL32-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2440-6HL32-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2440-6HL32-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB delivers — and what the ratings mean for your panel

The Siemens SENTRON 3VA2440-6HL32-0DL0 is a 3-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 400 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling, which simplifies panel thermal budgeting in a warm enclosure. Its interrupting capacity hits 242 kA at 240 V, 187 kA at 415 V and 440 V, and 121 kA at 500 V — numbers that put it squarely in high-fault-duty territory for industrial switchboards and transformer secondaries where available fault current is substantial. At 690 V the interrupting rating drops to 9 kA, so if your circuit runs at that voltage, verify the upstream fault level stays within that envelope. The breaker includes an undervoltage release (UVR) and a complement of auxiliary switches: two auxiliary switches plus one trip alarm switch and one electrical alarm switch (HQ configuration), giving the controls integrator status feedback without adding external relays. Maximum power loss is 66 W — a figure to factor into enclosure ventilation if the MCCB is tightly grouped with other heat sources.

Mounting and integration notes

Dimensions are 248 mm high, 138 mm wide, and 110 mm deep — a standard SENTRON 3VA frame size that fits existing 3VA panel cutouts and busbar arrangements. The basic switch variant is listed as 3VA2440-6HL32-0AA0; the -0DL0 suffix adds the UVR and the HQ auxiliary switch configuration, so if you are replacing a bare switch, confirm the accessory stack matches your control voltage.

Selectivity and coordination considerations

The breaker carries a 5 kA rating limited to 1 second — a short-time withstand figure that matters for selective coordination downstream of a larger feeder: it lets a downstream device clear a fault before this breaker trips, provided the fault current and duration stay under that threshold. A trip indicator is fitted, so a maintenance technician can visually confirm the breaker has opened on fault without needing to reset and re-energize to check.

Frequently asked questions

Will 3VA2440-6HL32-0DL0 drop into a panel specified around 3VA2225-5HN42-0BB0?

Both are SENTRON 3VA frame breakers, so the physical footprint (248 x 138 x 110 mm) and busbar centers are the same — it will mount in the same cutout without rewiring the bus, but verify the 400 A rating and the auxiliary switch configuration (HQ + UVR) match your control scheme.

MPN
3VA2440-6HL32-0DL0