Skip to main content
Siemens 3VA2440-7HL32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-7HL32-0AB0 SENTRON MCCB, 400 A, 3-Pole, 4800

MPN3VA2440-7HL32-0AB0

Siemens SENTRON 3VA2, molded case circuit breaker, 3VA2440-7HL32-0AB0, 3-pole, 400 A rated, 4800 A max, 330 kA at 240 V, line protection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-7HL32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2440-7HL32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W
3VA2440-7HL32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2440-7HL32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-7HL32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2440-7HL32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-7HL32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA2440-7HL32-0AB0 is a SENTRON molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 400 A across the full ambient range from 40 °C to 70 °C with no derating needed — that's the same 400 A at 70 °C as at 40 °C, so you don't lose headroom in a hot panel.

SCCR and interrupting capacity

Interrupting capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and drops to 9 kA at 690 V — the 690 V figure is the one to watch if you're on a 690 V line; that's a significant step down from the 500 V rating. Maximum rating is 4800 A, minimum 600 A, with a short-time withstand of 5 kA limited to 1 second.

Physical fit and auxiliary switches

Dimensions are 138 mm wide, 248 mm high, 110 mm deep — that's a 5.43 by 9.76 by 4.33 inch footprint, so check your panel gland plate and DIN-rail spacing before committing. Comes with 2 auxiliary switches (HP design) built in; no auxiliary release fitted, no trip indicator, no voltage trigger.

Frequently asked questions

Does 3VA2440-7HL32-0AB0 include ground-fault monitoring or a trip indicator?

No — no ground-fault monitoring, no trip indicator, no undervoltage release, and no communication function.

MPN
3VA2440-7HL32-0AB0