Siemens 3VA2440-7HL32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-7HL32-0AH0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2440-7HL32-0AH0

Siemens SENTRON 3VA2440-7HL32-0AH0, molded case circuit breaker, 3-pole, 400 A, line protection, with 2 auxiliary switches + 1 trip alarm switch HQ.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2440-7HL32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-7HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2440-7HL32-0AH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W

Protection & Trip Unit

3VA2440-7HL32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2440-7HL32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2440-7HL32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2440-7HL32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2440-7HL32-0AH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this MCCB delivers

The Siemens 3VA2440-7HL32-0AH0 is a SENTRON molded case circuit breaker (MCCB) rated for 400 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to the maximum operating temperature. That makes it a straightforward choice for high-ambient panels, compressor rooms, or outdoor enclosures where other breakers would require a larger frame. Breaking capacity is the headline here: 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 9 kA at 690 V. These are high-interrupting ratings for a 400 A frame — it handles fault currents that would vaporize a standard industrial MCCB, so it fits at the main or large feeder position where available fault current is high. The adjustable thermal-magnetic trip range spans 600 A to 4800 A (likely the instantaneous magnetic pickup range; the 400 A continuous frame sets the thermal element). That wide adjustment band lets you coordinate selectively with downstream breakers without swapping the entire unit.

Panel fit and wiring

Dimensions are 248 mm high × 138 mm wide × 110 mm deep. The 138 mm width (5.43 in) fits three-pole spacing on a DIN rail. Maximum power dissipation is 63.5 W. In a sealed enclosure, that heat needs to be factored into the thermal budget — at full load it's roughly the same as a small soldering iron running continuously inside the panel. Comes with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). That's enough for remote status indication (open/closed/tripped) without adding external relays. No undervoltage release or ground-fault monitoring on this variant — those are separate order options if your safety circuit requires them.

Lifecycle and sourcing posture

Operating temperature range is -25 °C to +70 °C; storage range is -40 °C to +80 °C. The storage minimum is the more restrictive limit for warehousing — keep it above -40 °C and the molded case stays compliant.

Frequently asked questions

Does 3VA2440-7HL32-0AH0 include auxiliary switches?

Yes, it comes with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration). No undervoltage release or ground-fault monitoring is included on this variant.

MPN
3VA2440-7HL32-0AH0