Skip to main content
Siemens 3VA2440-7HL32-0DA0 — Molded Case Circuit Breakers (MCCB)

3VA2440-7HL32-0DA0 SENTRON MCCB, 3-pole, 600–4800 A, 400 A c

MPN3VA2440-7HL32-0DA0

Siemens SENTRON 3VA2440-7HL32-0DA0 molded case circuit breaker, 3-pole, adjustable 600–4800 A, 400 A continuous at 70 °C, interrupting capacity 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-7HL32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2440-7HL32-0AA0
3VA2440-7HL32-0DA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.66 W
3VA2440-7HL32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2440-7HL32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-7HL32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2440-7HL32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-7HL32-0DA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

It carries an adjustable continuous current range from 600 A minimum to 4800 A maximum, and delivers 400 A continuous at ambient temperatures from 40 °C all the way up to 70 °C — no derating needed across that span. That means you can bolt this into a hot panel or a crusher drive cabinet without losing headroom.

Interrupting capacity — what it stops

Interrupting capacity climbs with available fault current: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 9 kA at 690 V. A 5 kA limited-to-1-second rating handles short-time withstand for coordination studies.

Build and fit

The base switch is order code 3VA2440-7HL32-0AA0. No communication function onboard — this is a standalone line-protection breaker, not a smart trip unit.

MPN
3VA2440-7HL32-0DA0