Siemens 3VA2440-7KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-7KQ42-0AA0 SENTRON MCCB, 400 A, 4-Pole, ETU8

MPN3VA2440-7KQ42-0AA0
Active

Siemens SENTRON 3VA2440-7KQ42-0AA0, molded case circuit breaker, 4-pole, 400 A, ETU860 electronic trip unit, breaking capacity 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-7KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2440-7KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C376 A
Current at 60 °C352 A
Current at 65 °C324 A
Current at 70 °C300 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.3 W
3VA2440-7KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
3VA2440-7KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-7KQ42-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2440-7KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-7KQ42-0AA0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.8 in
Width (in)7.2 in
Depth (in)4.3 in

Product details

It delivers a breaking capacity of 330 kA at 240 V, tapering to 242 kA at 415 V and 440 V, then 187 kA at 500 V, and 9 kA at 690 V — the 690 V figure is the one to watch for 690 V line-side faults; at that voltage the breaker is still adequate for most downstream coordination but the margin narrows. The ETU860 provides adjustable N-conductor protection (OFF, 20 % to 130 %) and ground-fault monitoring via summation current formation on L+N, so it handles both phase and residual current detection without a separate module.

Thermal derating and integration

The breaker carries its full 400 A rating up to 50 °C ambient; above that it derates to 376 A at 55 °C, 352 A at 60 °C, 324 A at 65 °C, and 300 A at 70 °C. For a panel builder, that means a 400 A bus can be served without oversizing the breaker as long as the enclosure ambient stays under 50 °C — beyond that, the derating curve governs the actual ampacity. The maximum power loss is 63.3 W, so ventilation or spacing in a sealed enclosure should account for that heat.

Frequently asked questions

What is the breaking capacity of 3VA2440-7KQ42-0AA0 at 415 V?

At 415 V the breaking capacity is 242 kA; at 240 V it is 330 kA, and at 690 V it drops to 9 kA.

What trip unit does this MCCB use?

It uses the ETU860 electronic trip unit with adjustable N-conductor protection (OFF, 20 % to 130 %) and ground-fault monitoring via summation current on L+N.

Where can I buy 3VA2440-7KQ42-0AA0?

This part is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
3VA2440-7KQ42-0AA0