Skip to main content
Siemens 3VA2440-7MQ32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-7MQ32-0AA0 SENTRON MCCB, 400 A, 3-Pole

MPN3VA2440-7MQ32-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2440-7MQ32-0AA0, 400 A, 3-pole, motor protection design, 330 kA interrupting capacity at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2440-7MQ32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2440-7MQ32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V9 kA
Power loss, max.63.5 W

Protection & Trip Unit

3VA2440-7MQ32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860M
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes

Construction & Connection

3VA2440-7MQ32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2440-7MQ32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2440-7MQ32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2440-7MQ32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this 400 A MCCB does on your line

The Siemens 3VA2440-7MQ32-0AA0 is a SENTRON molded case circuit breaker (MCCB) rated for continuous 400 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That means it holds its full 400 A rating in a warm panel, not just on a cool bench. Three-pole construction with motor protection design, so it's built to handle induction motor starts and overload profiles, not just resistive heater banks. Phase failure detection and ground-fault monitoring via summation current formation on the L-conductor are onboard — it catches a lost phase or a ground leak without an add-on module. Interrupting capacity hits 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 9 kA at 690 V. That 330 kA figure at 240 V is the headline number for high-fault panels near a transformer or large motor bank — it clears a bolted fault without the arc flash escalating upstream.

Sourcing and lifecycle — still a current-production part

This 3VA2440-7MQ32-0AA0 carries a lifecycle status of 'current', meaning Siemens still manufactures it as an active catalog item. No last-time-buy notice, no successor code to track — it's the standard offering in the 3VA2 motor-protection MCCB family. For BOM freeze or PCN-watch purposes, this is a stable line. The 3VA2 series has been the SENTRON MCCB platform for several years; no phase-out signals on this rating. Sourced and quoted to order through independent distribution — availability and current pricing confirmed at quote time.

Panel fit and integration

Dimensions: 248 mm high, 138 mm wide, 110 mm deep. That 110 mm depth is the critical number for shallow backpanel enclosures — verify your cabinet depth clears it with wiring space behind. Width of 138 mm is standard for a 400 A frame; it occupies three pole spaces on the DIN rail or mounting plate. Communication function is built in — this variant supports the 3VA2 communication module for remote trip indication and power monitoring over PROFIBUS or PROFINET, depending on the plug-in module selected separately. No separate voltage trigger or undervoltage release on this order code; those are add-on accessories. Power loss at full load is 63.5 W maximum — that's the heat to sink into the panel's thermal budget. Operating temperature range -25 °C to 70 °C; storage from -40 °C to 80 °C.

Protection settings and trip characteristics

Adjustable overload protection: initial value set at 80 A, full-scale value 400 A. That's a 5:1 adjustment range — you can dial the thermal-magnetic trip down to 80 A for a smaller motor or up to 400 A for the full frame rating. Short-time delay adjustable from 3 s minimum to 25 s maximum, giving selectivity coordination with downstream breakers. Short-circuit withstand: limited to 5 kA at 1 second — this is the short-time withstand rating for selective coordination. No trip indicator, so remote signaling requires the communication module or auxiliary contacts.

Frequently asked questions

Who supplies 3VA2440-7MQ32-0AA0 and how is it quoted for volume purchases?

This MCCB is sourced and quoted to order through independent industrial distribution. Submit an RFQ for current pricing and availability — no minimums, but volume pricing applies at quantity breaks.

What is the interrupting capacity of 3VA2440-7MQ32-0AA0 at 240 V?

330 kA at 240 V, which covers high-fault installations near transformers or large motor banks.

What compliance documentation does this brand provide for 3VA2440-7MQ32-0AA0?

Siemens SENTRON MCCBs typically carry UL 489, CSA C22.2 No. 5, IEC 60947-2, and CE marking. RoHS and REACH declarations are available from Siemens documentation. Specific certification markings should be verified against the nameplate on the unit received.

MPN
3VA2440-7MQ32-0AA0