Skip to main content
Siemens 3VA2440-8HM32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-8HM32-0AA0 MCCB, 400 A, 150 kA @ 415 V

MPN3VA2440-8HM32-0AA0
Active

Siemens 3VA Molded Case Circuit Breaker, IEC frame 630 A, 3-pole, breaking capacity class L Icu=150 kA @ 415 V, line protection ETU330 with LIG functions, In=400 A.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Specifications

3VA2440-8HM32-0AA0 — Specifications
ParameterValue
Group codeP360
Product group5374
Product classC: products manufactured / produced to order, which cannot be reused or re-utilized or be returned against credit.
Series3VA Molded Case Circuit Breakers up to 1600 A, IEC
Export control regulationsAL : N / ECCN : 9N9999
Compliance with the substance restrictions according to RoHS directiveSince: 01-04-14

Product details

Protection and coordination for a 400 A feeder

The Siemens 3VA2440-8HM32-0AA0 is a 3-pole IEC molded case circuit breaker on a 630 A frame, fitted with an ETU330 electronic trip unit and rated In=400 A. The breaking capacity class L delivers Icu=150 kA at 415 V — that is the maximum fault current it can safely interrupt without upstream cascading, sized for high-fault industrial distribution where the available short-circuit current is substantial. The ETU330 provides LIG protection: long-time (overload) adjustable Ir=160…400 A, short-time (instantaneous) Ii=1.5…11 x In, and ground-fault Ig=0.2…1 x In with time delay tg=0.1/0.3 s. That ground-fault element is the key difference from a standard LI-only trip — it detects leakage to earth, which matters for personnel protection and equipment damage prevention on ungrounded or resistance-grounded systems.

Sourcing and lifecycle — active, built to order

Packaging is a single piece (265 x 165 x 170 mm). The unit is RoHS compliant since 01-04-14, with a REACH Article 33 notification for Lead (CAS 7439-92-1) above 0.1% w/w. Export control is AL:N / ECCN:9N9999.

Selectivity and coordination notes

The 3VA2 frame with 150 kA Icu at 415 V sits in the high-breaking-capacity tier of the 3VA family. For a 400 A feeder, the adjustable L and I settings let you coordinate downstream with smaller MCCBs or fused switches — the wide Ii range (1.5–11 x In) gives room to ride through motor inrush while still clearing a bolted fault. The ground-fault element adds a separate coordination layer for earth faults, which a standard thermal-magnetic breaker cannot do.

Frequently asked questions

What is the breaking capacity of this breaker?

The 3VA2440-8HM32-0AA0 is rated Icu=150 kA at 415 V, which is the maximum short-circuit current it can safely interrupt. This places it in breaking capacity class L within the 3VA IEC family.

What trip unit does this MCCB use and what protections does it offer?

It uses an ETU330 electronic trip unit with LIG protection: long-time overload (Ir=160…400 A), instantaneous short-circuit (Ii=1.5…11 x In), and ground-fault (Ig=0.2…1 x In with tg=0.1/0.3 s). The ground-fault function detects earth leakage, which a standard LI trip cannot.

How is 3VA2440-8HM32-0AA0 supplied and quoted for volume purchases?

This part is manufactured to order (Product class C) and is sourced through independent distribution. Volume pricing and lead time are confirmed at quote time against an RFQ — no stock is held on the shelf.

What compliance documentation does this breaker carry?

RoHS compliant since 01-04-14. REACH Article 33 notification for Lead (CAS 7439-92-1) above 0.1% w/w. Export control classification is AL:N / ECCN:9N9999. The product family is designed to IEC 60947-2.

MPN
3VA2440-8HM32-0AA0