Skip to main content
Siemens 3VA2440-8HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2440-8HN32-0AA0 SENTRON MCCB, 400 A, 3-Pole, ETU3

MPN3VA2440-8HN32-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), line protection, 3-pole, 400 A, ETU350 electronic trip unit, 440 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2440-8HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2440-8HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C400 A
Current at 60 °C400 A
Current at 65 °C400 A
Current at 70 °C400 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.63.5 W
3VA2440-8HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2440-8HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2440-8HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2440-8HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2440-8HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this 3VA2 MCCB brings to a 400 A feeder

That matters when you need selectivity downstream or want to dial in coordination with a transformer inrush or motor starting profile. No derating curve to chase inside a hot panel. The interrupting capacity runs 440 kA at 240 V, 330 kA at 415/440 V, 220 kA at 500 V, and 52.5 kA at 690 V (–) — that's serious fault-clearing headroom for a 400 A frame, especially on a 480 V or 600 V class distribution board where SCCR requirements climb. This is a straight feeder breaker — no frills, no auxiliary electronics to fail. The 63.5 W maximum power loss is the heat you need to vent; factor it into the enclosure sizing if the panel is tight.

Panel fit and footprint

The 3VA2440-8HN32-0AA0 measures 248 mm tall, 138 mm wide, and 110 mm deep. No condensation allowed during operation — standard MCCB practice.

Frequently asked questions

How do I get pricing and availability for 3VA2440-8HN32-0AA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels. No stock or price figures are published here.

What are the key interrupting ratings for this MCCB?

440 kA at 240 V, 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V (–). These are the maximum fault currents the breaker can safely interrupt at each voltage level.

What is the panel footprint of the 3VA2440-8HN32-0AA0?

248 mm tall, 138 mm wide, 110 mm deep. The 138 mm width is standard for a 3-pole 400 A frame MCCB.

MPN
3VA2440-8HN32-0AA0