Skip to main content
Siemens 3VA2450-5MN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2450-5MN32-0AA0 MCCB, 500 A, 3-Pole

MPN3VA2450-5MN32-0AA0
Active

Siemens SENTRON 3VA2450-5MN32-0AA0, 3-pole molded case circuit breaker, 500 A continuous rated current, 187 kA breaking capacity at 240 V, motor protection design.

$993.14Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2450-5MN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2450-5MN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.99 W
3VA2450-5MN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2450-5MN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-5MN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2450-5MN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-5MN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

What this 500 A MCCB does on the line

The Siemens SENTRON 3VA2450-5MN32-0AA0 is a 3-pole molded case circuit breaker rated for 500 A continuous current at 40 °C, and it holds that rating all the way up to 50 °C before it starts to derate — 495 A at 55 °C, 490 A at 60 °C, 485 A at 65 °C, 480 A at 70 °C. That thermal profile means you can run it near full nameplate in a warm panel without oversizing the frame. Breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V. The design is specifically for motor protection, with phase failure detection built in, no undervoltage release, and no ground-fault monitoring version.

Panel fit and power loss

Maximum power loss is 99 W, so plan for that heat in the enclosure: it's not a sealed-box part unless you've got ventilation or a bigger can.

Frequently asked questions

Where can I buy 3VA2450-5MN32-0AA0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote — no stock figures or lead-time numbers are published here.

What are the key ratings for 3VA2450-5MN32-0AA0?

500 A continuous at 40 °C, 187 kA breaking capacity at 240 V, 3-pole motor protection design with phase failure detection.

MPN
3VA2450-5MN32-0AA0