Siemens 3VA2450-5MN32-0AC0 SENTRON MCCB, 500 A, 187 kA

MPN3VA2450-5MN32-0AC0

Siemens SENTRON 3VA2450-5MN32-0AC0, molded case circuit breaker, 3-pole, 500 A rated continuous current, ETU350M electronic trip unit, 187 kA interrupting capacity at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2450-5MN32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2450-5MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2450-5MN32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.99 W
3VA2450-5MN32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
3VA2450-5MN32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-5MN32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2450-5MN32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-5MN32-0AC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

It carries 187 kA interrupting capacity at 240 V AC, stepping down to 121 kA at 415/440 V and 75.6 kA at 500 V — enough headroom for most industrial main or feeder applications.

Three-pole construction, 138 mm wide, 248 mm tall, 110 mm deep — fits standard panel cutouts for 500 A frame MCCBs. Front IP40 protection keeps out tools and finger contact in enclosed switchboards. Max power dissipation is 99 W at rated load; account for that in enclosure thermal calculations, especially in a multi-breaker lineup.

The ETU350M overcurrent release provides phase failure detection — critical for motor protection applications where a single-phased condition can burn out a winding before the overload curve catches it. No undervoltage release or shunt trip fitted as standard; the basic switch variant (3VA2450-5MN32-0AA0) is the core breaker without auxiliaries if that's what the BOM calls for. Latching endurance rated at 15,000 operations, which is typical for a 500 A frame used in distribution rather than frequent switching duty.

Frequently asked questions

Where can I buy 3VA2450-5MN32-0AC0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What are the key ratings for 3VA2450-5MN32-0AC0?

Rated continuous current (Iu) is 500 A at 40 °C ambient, with minor derating to 480 A at 70 °C. Interrupting capacity reaches 187 kA at 240 V AC, 121 kA at 415/440 V, and 75.6 kA at 500 V. Rated insulation voltage is 800 V. The ETU350M electronic trip unit handles adjustable overload and short-circuit protection with phase failure detection.

MPN
3VA2450-5MN32-0AC0