Skip to main content
Siemens 3VA2450-5MN32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2450-5MN32-0CA0 SENTRON MCCB, 500 A, 3-Pole, ETU3

MPN3VA2450-5MN32-0CA0

Siemens SENTRON 3VA2450-5MN32-0CA0, Molded case circuit breaker, 3-pole, 500 A rated continuous current, ETU350M electronic trip unit, undervoltage release, 187 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2450-5MN32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2450-5MN32-0AA0
3VA2450-5MN32-0CA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.101.5 W
3VA2450-5MN32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
3VA2450-5MN32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-5MN32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2450-5MN32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-5MN32-0CA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

MCCB for high-current motor protection

It carries a 187 kA interrupting rating at 240 V, dropping to 121 kA at 415 V and 440 V, then 75.6 kA at 500 V, and 17 kA at 690 V — figures that define its fault-clearing capability at the panel's supply voltage. An integrated undervoltage release (UVR) is fitted as standard; the auxiliary release is the 3VA9608-0BB24 module.

Dimensions are 248 mm high x 138 mm wide x 110 mm deep, designed for panel mounting with busbar or cable connections.

Protection and compliance details

Maximum power loss is 101.5 W; no auxiliary contacts or communication module are included on this variant.

Frequently asked questions

Where can I buy 3VA2450-5MN32-0CA0 and how do I get a price?

This MCCB is sourced to order through our industrial-automation distribution channel. Submit an RFQ; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2450-5MN32-0CA0 at 415 V?

The interrupting rating is 121 kA at 415 V (and at 440 V); at 240 V it is 187 kA.

Does this MCCB include an undervoltage release?

Yes, the 3VA2450-5MN32-0CA0 ships with an undervoltage release (UVR) as the auxiliary release.

What are the physical dimensions of 3VA2450-5MN32-0CA0?

Height 248 mm, width 138 mm, depth 110 mm.

What is the closest functional second-source to 3VA2450-5MN32-0CA0?

The peer 3VA1112-5EF32-0CA0 is a different SENTRON frame size and rating; it does not drop into the same panel without rewiring. The 3VA2450-5MN32-0CA0 is a 500 A, 3-pole, ETU350M unit — verify the peer's ampere and trip curve before substituting.

MPN
3VA2450-5MN32-0CA0