Siemens 3VA2450-5MN32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2450-5MN32-0HC0 SENTRON MCCB, 500 A, 3-Pole, Moto

MPN3VA2450-5MN32-0HC0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2450-5MN32-0HC0, 500 A, 3-pole, motor protection design, 121 kA at 415 V, with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2450-5MN32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2450-5MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2450-5MN32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.99 W

Protection & Trip Unit

3VA2450-5MN32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2450-5MN32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2450-5MN32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2450-5MN32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2450-5MN32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

SENTRON 3VA2 — 500 A MCCB for Motor Protection

The Siemens 3VA2450-5MN32-0HC0 is a SENTRON-series molded case circuit breaker (MCCB) designed specifically for motor protection, rated 500 A continuous at 40 °C through 50 °C ambient. It carries a 3-pole configuration with an integrated shunt trip (STL) and two auxiliary switches (HQ) factory-fitted, so it arrives ready for remote trip and status feedback without additional wiring modules. Breaking capacity is 121 kA at 415 V and 440 V, dropping to 75.6 kA at 500 V and 9 kA at 690 V — figures that suit it for high-fault industrial distribution downstream of a transformer or upstream of motor control centers. The 187 kA rating at 240 V confirms it handles the worst-case bolted fault on a 240 V delta secondary.

Thermal Derating and Continuous Current

The breaker holds 500 A from 40 °C to 50 °C without derating. Above that, it steps down: 495 A at 55 °C, 490 A at 60 °C, 485 A at 65 °C, and 480 A at 70 °C. For a panel that runs warm — say a 55 °C internal ambient — you lose 5 A of headroom, not enough to force a frame-size jump, but worth confirming against the motor FLA plus service factor. Maximum power loss is 99 W at rated load. That heat stays inside the enclosure; factor it into the panel's thermal budget if the MCCB shares a compartment with solid-state drives or PLCs.

Dimensions and Panel Fit

Footprint is 138 mm wide by 248 mm tall by 110 mm deep (5.43 × 9.76 × 4.33 in).

Integrated Auxiliaries and Releases

Factory-installed shunt trip (STL) allows remote tripping from a PLC or E-stop circuit. Two auxiliary switches (HQ) provide normally-open and normally-closed contacts for status feedback — one pair for the breaker's open/closed state, the other for trip indication. No separate auxiliary switch block to order and snap on. Phase failure detection is built into the motor-protection curve. Undervoltage release is not fitted on this variant; if UVR is required, the 3VA2450-5MN32-0AA0 basic switch is the starting point for adding one.

MPN
3VA2450-5MN32-0HC0