Skip to main content
Siemens 3VA2450-5MN32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2450-5MN32-0KL0 SENTRON MCCB, 500 A, 3-Pole, 121

MPN3VA2450-5MN32-0KL0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2450-5MN32-0KL0, 500 A at 40 °C, 3-pole, 121 kA at 415 V, motor protection design with shunt trip and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2450-5MN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2450-5MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2450-5MN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.99 W
3VA2450-5MN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2450-5MN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-5MN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2450-5MN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-5MN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA2450-5MN32-0KL0 is a SENTRON molded case circuit breaker (MCCB) rated 500 A continuous at 40 °C, with a 3-pole frame and a breaking capacity of 121 kA at 415 V AC. The basic switch core is order code 3VA2450-5MN32-0AA0.

This MCCB's interrupting rating drops as line voltage rises — a standard characteristic for any molded case breaker. At 240 V it handles 187 kA; at 415 V and 440 V it holds 121 kA; at 500 V it's 75.6 kA; at 690 V it's 9 kA. For a 480 V panel (common in North America), the 75.6 kA at 500 V is the relevant figure — that's well above typical 480 V available fault currents in most distribution boards.

Above that, it derates: 495 A at 55 °C, 490 A at 60 °C, 485 A at 65 °C, and 480 A at 70 °C (–).

Frequently asked questions

How do I get current pricing and availability for 3VA2450-5MN32-0KL0?

Pricing and availability are confirmed at quote time against an RFQ through independent distribution. Submit an RFQ for current figures.

What is the breaking capacity of 3VA2450-5MN32-0KL0 at 415 V?

At 415 V AC, the breaking capacity is 121 kA. At 240 V it is 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 9 kA.

Does 3VA2450-5MN32-0KL0 include a shunt trip and auxiliary switches?

Yes, it includes a shunt trip release (STL) for remote tripping, plus two auxiliary switches, one trip alarm switch, and one electrical alarm switch.

MPN
3VA2450-5MN32-0KL0