Siemens 3VA2450-7MN32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2450-7MN32-0DA0 MCCB, 500 A, 330 kA at 24

MPN3VA2450-7MN32-0DA0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2450-7MN32-0DA0, 3-pole, 500 A rated continuous current Iu, 330 kA breaking capacity at 240 V, ETU350M electronic trip unit, undervoltage release, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2450-7MN32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2450-7MN32-0AA0

Ratings

3VA2450-7MN32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.101.5 W

Protection & Trip Unit

3VA2450-7MN32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M

Construction & Connection

3VA2450-7MN32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2450-7MN32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2450-7MN32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2450-7MN32-0DA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

What the ratings mean for your panel

The Siemens SENTRON 3VA2450-7MN32-0DA0 is a 3-pole molded case circuit breaker (MCCB) rated for 500 A continuous current Iu across the full 40 °C to 50 °C band — no derating needed in a typical 40 °C switchroom. Above that, the thermal curve drops it to 495 A at 55 °C, 490 A at 60 °C, 485 A at 65 °C, and 480 A at 70 °C. That 500 A frame is the one that matters for a 500 A bus or feeder; if your ambient runs 55 °C+, you size for the derated figure. Breaking capacity is the headline: 330 kA at 240 V, 242 kA at 415 V and 440 V, and 52.5 kA at 690 V. That 330 kA at 240 V is exceptional — it means this breaker can interrupt a fault at a 240 V transformer secondary or a large motor centre without needing a current-limiting upstream device. At 415 V, 242 kA still clears most industrial fault levels; at 690 V the 52.5 kA rating is typical for a 500 A frame and suits the majority of 690 V distribution. The ETU350M electronic trip unit handles the overcurrent protection — adjustable long-time, short-time, and instantaneous settings via the front dials. Phase failure detection is built in, so it will trip on a lost phase, protecting motors and other three-phase loads. There is no ground-fault monitoring on this variant; if you need that, you step to a 3VA2 with the GF option. An undervoltage release (UVR) is fitted as standard — the part includes the 3VA9608-0BB25 auxiliary trip module. That means the breaker drops out on loss of control voltage, which is common in safety circuits and emergency-stop chains. No auxiliary contacts are included; if you need status feedback to a PLC, order the contact block separately.

Sourcing and lifecycle

The basic switch assembly carries the order code 3VA2450-7MN32-0AA0. If you are replacing only the internal switch mechanism (not the entire breaker), that is the sub-assembly to order. The auxiliary trip module is 3VA9608-0BB25.

Mounting and integration

Dimensions: 248 mm high, 138 mm wide, 110 mm deep. That 138 mm width is a standard 3-pole MCCB footprint — it fits the usual panel cut-out and bus-bar spacing for a 500 A frame. The IP40 rating on the front means it is protected against tools and wires >1 mm, but not against moisture; install it inside a cabinet rated for the environment. Maximum power loss is 101.5 W — factor that into your enclosure thermal calculation if the panel is densely packed. Operating temperature range is -25 °C to 70 °C. Storage range is -40 °C to 80 °C. The 15 000 latching endurance cycles is typical for a 500 A MCCB in distribution duty — not intended for frequent switching like a contactor, but fine for isolation and backup protection.

Frequently asked questions

How do I get current pricing and availability for 3VA2450-7MN32-0DA0?

Pricing and availability are confirmed at quote time. Submit an RFQ through the storefront — the part is sourced to order through independent distribution channels.

What are the key ratings of the 3VA2450-7MN32-0DA0?

Rated continuous current Iu is 500 A, with breaking capacity of 330 kA at 240 V, 242 kA at 415 V and 440 V, and 52.5 kA at 690 V. It is a 3-pole MCCB with an ETU350M electronic trip unit and built-in phase failure detection.

MPN
3VA2450-7MN32-0DA0