Skip to main content
Siemens 3VA2450-7MN32-0HC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2450-7MN32-0HC0 SENTRON MCCB, 500 A, 330 kA at 24

MPN3VA2450-7MN32-0HC0

Siemens SENTRON 3VA2450-7MN32-0HC0, molded case circuit breaker, 3-pole, 500 A at 40 °C, 330 kA breaking at 240 V, motor protection design with shunt trip and two auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2450-7MN32-0HC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2450-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2450-7MN32-0HC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V15.3 kA
Power loss, max.99 W
3VA2450-7MN32-0HC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2450-7MN32-0HC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-7MN32-0HC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2450-7MN32-0HC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-7MN32-0HC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens SENTRON 3VA2450-7MN32-0HC0 is a 3-pole molded case circuit breaker (MCCB) rated for 500 A continuous at 40 °C, with a maximum breaking capacity of 330 kA at 240 V AC — that figure drops to 242 kA at 415 V and 187 kA at 500 V, so selectivity studies need the actual fault level at the point of installation. Rated current holds flat at 500 A up to 50 °C ambient, then derates to 495 A at 55 °C and 480 A at 70 °C — useful if the breaker sits in a warm enclosure near other heat sources.

Maximum power loss is 99 W — relevant for enclosure thermal calculations and ventilation sizing. The short-time withstand rating is 6 kA limited to 1 second — coordination engineers need this for downstream selectivity with smaller breakers.

Frequently asked questions

Where can I buy 3VA2450-7MN32-0HC0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2450-7MN32-0HC0 at 415 V?

At 415 V AC the breaking capacity is 242 kA.

Does 3VA2450-7MN32-0HC0 include phase failure detection?

Yes, phase failure detection is built into this motor-protection design.

MPN
3VA2450-7MN32-0HC0