Siemens 3VA2450-7MN32-0HL0 SENTRON MCCB, 500 A, 330 kA

MPN3VA2450-7MN32-0HL0

Siemens SENTRON 3VA2 molded case circuit breaker, motor protection version, 500 A rated continuous current, 3-pole, ETU350M electronic trip unit, 330 kA breaking capacity at 240 V AC, shunt trip STL, auxiliary switches 2+1+1 HQ, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2450-7MN32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2450-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2450-7MN32-0HL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.99 W
3VA2450-7MN32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
3VA2450-7MN32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-7MN32-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2450-7MN32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-7MN32-0HL0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

That 500 A holds flat from 40 °C up to 50 °C ambient, then derates gradually to 480 A at 70 °C — so in a warm panel you still get nearly full rating without oversizing the frame. Breaking capacity is the headline here: 330 kA at 240 V AC, 242 kA at 415 V and 440 V, and 52.5 kA at 690 V. The ETU350M electronic trip unit handles the protection curve. It includes phase failure detection, so a lost phase on a motor circuit trips the breaker rather than letting the motor single-phase and burn. The shunt trip (STL) auxiliary release lets a remote signal or safety circuit force the breaker open independently of the trip unit.

This MCCB measures 248 mm high by 138 mm wide by 110 mm deep — a standard 3-pole frame size for the 3VA2 series. It mounts via screw terminals to a backplate or mounting plate inside an enclosure; no DIN-rail clip on this class of breaker. The IP40 front protection means it's suitable for indoor panel installation where tools are required to access live parts. That gives you four discrete signals for status feedback — breaker open/closed, trip event, and an electrical alarm contact for remote annunciation.

It lives in industrial switchboards, motor control centers, and distribution panels where a 500 A feeder or large motor branch needs electronic trip protection with high fault-interrupting capability. No undervoltage release, no ground fault monitoring, and no communication function on this variant — it's a straightforward power breaker with shunt trip and auxiliary contacts.

Frequently asked questions

What trip unit does the 3VA2450-7MN32-0HL0 use?

It uses the ETU350M electronic overcurrent release with phase failure detection and a shunt trip (STL) auxiliary release.

MPN