Skip to main content
Siemens 3VA2450-7MN32-0JA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2450-7MN32-0JA0 SENTRON MCCB, 500 A, 3-Pole, Moto

MPN3VA2450-7MN32-0JA0

Siemens SENTRON 3VA2450-7MN32-0JA0, molded case circuit breaker, 3-pole, motor protection version, rated continuous current 500 A, ETU350M overcurrent release, shunt trip (STL), breaking capacity 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2450-7MN32-0JA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2450-7MN32-0AA0
3VA2450-7MN32-0JA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.99 W
3VA2450-7MN32-0JA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
3VA2450-7MN32-0JA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-7MN32-0JA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2450-7MN32-0JA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-7MN32-0JA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

At 55 °C it carries 495 A, and at 70 °C still holds 480 A, so it handles warm enclosures without a frame size jump. Breaking capacity is the headline: 330 kA at 240 V, 242 kA at 415 V and 440 V, and 52.5 kA at 690 V.

Front IP40 protection keeps out tools and fingers; the back and sides rely on the enclosure. The basic switch core is order code 3VA2450-7MN32-0AA0, and the integrated shunt trip is 3VA9688-0BL32, so replacement or spare-part ordering is direct.

Frequently asked questions

What is the breaking capacity of this MCCB?

330 kA at 240 V, 242 kA at 415 V and 440 V, and 52.5 kA at 690 V. That covers high-fault industrial feeds.

Where can I buy the 3VA2450-7MN32-0JA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

What trip unit does this breaker use?

An ETU350M electronic overcurrent release with phase failure detection and a shunt trip (STL) auxiliary release.

MPN
3VA2450-7MN32-0JA0