Skip to main content
Siemens 3VA2450-7MQ32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2450-7MQ32-0AA0 SENTRON MCCB, 500 A, 3-Pole, Moto

MPN3VA2450-7MQ32-0AA0
Active

Siemens SENTRON 3VA2450-7MQ32-0AA0, molded case circuit breaker, 3-pole, 500 A at 40 °C, motor protection design, breaking capacity 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2450-7MQ32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2450-7MQ32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C477 A
Current at 60 °C455 A
Current at 65 °C432 A
Current at 70 °C410 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V15.3 kA
Power loss, max.99 W
3VA2450-7MQ32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860M
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2450-7MQ32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-7MQ32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2450-7MQ32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-7MQ32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The 3VA2450-7MQ32-0AA0: Rated 500 A at 40 °C, with full thermal derating provided up to 70 °C (432 A at 65 °C, 410 A at 70 °C), so the installer sizes the breaker for the actual enclosure ambient, not the nameplate. Breaking capacity runs from 330 kA at 240 V down to 15.3 kA at 690 V — the 242 kA at 415 V and 440 V covers the common European low-voltage distribution levels without a cascading upstream breaker. Adjustable overload pickup from 100 A to 500 A full-scale, with short-time delay settable between 3 s and 13 s, giving the commissioning engineer selectivity coordination headroom against downstream feeders.

Protection and communication functions

A separate measurement function is also present, so the breaker can report load data without an external transducer. Communication function is integrated — no external module required for basic data exchange with the plant control system. No undervoltage release or trip indicator on this variant; the trip signal is carried over the communication link rather than a local flag.

Dimensions 138 mm wide, 248 mm high, 110 mm deep — standard SENTRON 3VA footprint for a 500 A frame. Panel cutout and busbar spacing match the 3VA family; no adapter plate needed for a 3VA retrofit into an existing 3WL or 3VL panel. Maximum power loss 99 W — factor into the enclosure thermal budget.

Frequently asked questions

How do I get current pricing and availability for 3VA2450-7MQ32-0AA0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels.

What is the breaking capacity of this MCCB at 415 V?

242 kA at 415 V, which covers the common European low-voltage distribution level without requiring an upstream current-limiting device.

What is the adjustable current range on the 3VA2450-7MQ32-0AA0?

Adjustable from 100 A to 500 A full-scale, with short-time delay settable between 3 s and 13 s for selectivity coordination.

Does this breaker include ground-fault protection?

Yes, it has ground-fault monitoring via summation current formation on the L-conductor, plus phase failure detection and a separate measurement function.

MPN
3VA2450-7MQ32-0AA0