Siemens SENTRON 3VA2450-7MS32-0AA0, molded case circuit breaker, 3-pole, 500 A continuous, 110 x 138 x 248 mm.

$932.18Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2450-7MS32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2450-7MS32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C500 A
Current at 45 °C500 A
Current at 50 °C500 A
Current at 55 °C495 A
Current at 60 °C490 A
Current at 65 °C485 A
Current at 70 °C480 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V15.3 kA
Power loss, max.99 W
3VA2450-7MS32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2450-7MS32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2450-7MS32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2450-7MS32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2450-7MS32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Temperature derating and panel fit

The 3VA2450-7MS32-0AA0 holds its full 500 A rating from 40 °C through 50 °C ambient. Above that it derates linearly: 495 A at 55 °C, 490 A at 60 °C, 485 A at 65 °C, and 480 A at 70 °C. Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. The case dimensions are 110 mm deep by 138 mm wide by 248 mm high — a standard MCCB footprint that fits most distribution panelboards and motor control center buckets. Maximum power loss is 99 W.

Frequently asked questions

What is the closest functional second-source for 3VA2450-7MS32-0AA0?

The closest functional peer in the same SENTRON family is the 3VA2216-7MS32-0KC0, but it is a different frame size and rating — verify dimensions and interrupting capacity before substituting. The 3VA2450-7MS32-0AA0 is a 500 A, 3-pole starter-protection MCCB; the 3VA2216-7MS32-0KC0 serves a different current class and may not drop into the same panel cutout without rewiring.

Where can I buy 3VA2450-7MS32-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN
3VA2450-7MS32-0AA0