Siemens 3VA2463-0HL32-0BE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-0HL32-0BE0 SENTRON MCCB, 630A, 440kA at 415V

MPN3VA2463-0HL32-0BE0

Siemens SENTRON 3VA2463-0HL32-0BE0, molded case circuit breaker, 3-pole, 630 A at 40 °C, ETU320 electronic trip unit LI, 440 kA at 415 V, 187 kA at 690 V, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2463-0HL32-0BE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2463-0HL32-0BE0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.164.5 W
3VA2463-0HL32-0BE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA2463-0HL32-0BE0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-0HL32-0BE0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2463-0HL32-0BE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-0HL32-0BE0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

630 A continuous, 440 kA interrupting — the mainline feeder breaker

The Siemens SENTRON 3VA2463-0HL32-0BE0 is a 3-pole molded case circuit breaker rated for 630 A continuous at 40 °C ambient, with a thermal derating curve that drops to 520 A at 70 °C. At 690 V the 187 kA rating still covers most industrial distribution systems. These numbers govern the upstream fuse or breaker coordination study. The ETU320 is a basic electronic trip unit with LI (long-time and instantaneous) protection only — no ground-fault, no short-time delay, no communication. If your coordination study requires short-time delay or ground-fault, this is not the variant. The LI curve is field-adjustable via DIP switches on the trip unit face.

Dimensions are 248 mm height, 138 mm width, 110 mm depth. The breaker ships with 4 auxiliary switches (HQ type) and an undervoltage release. No washdown or outdoor rating. The trip indicator is not present on this variant; trip status is read from the auxiliary contacts or the handle position.

Frequently asked questions

What trip unit does 3VA2463-0HL32-0BE0 use?

The ETU320 electronic trip unit with LI (long-time and instantaneous) protection only — no ground-fault, no short-time delay, no communication.