Skip to main content
Siemens 3VA2463-0KQ32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-0KQ32-0AA0 SENTRON MCCB, 630 A, 440 kA at 41

MPN3VA2463-0KQ32-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2463-0KQ32-0AA0, 3-pole, 630 A rated continuous current, ETU860 electronic trip unit, 440 kA breaking capacity at 415 V, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-0KQ32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2463-0KQ32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C600 A
Current at 50 °C570 A
Current at 55 °C540 A
Current at 60 °C510 A
Current at 65 °C480 A
Current at 70 °C450 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.162 W
3VA2463-0KQ32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2463-0KQ32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-0KQ32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2463-0KQ32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-0KQ32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

630 A MCCB with ETU860 — what the ratings decide

The Siemens SENTRON 3VA2463-0KQ32-0AA0 is a 3-pole molded case circuit breaker rated for 630 A continuous current at 40 °C, with an electronic trip unit ETU860 that handles adjustable N-conductor protection from OFF to 160 % of the phase setting.

The 630 A rating holds only at 40 °C ambient. Above that, the continuous current must be derated: 600 A at 45 °C, 570 A at 50 °C, 540 A at 55 °C, 510 A at 60 °C, 480 A at 65 °C, and 450 A at 70 °C. The maximum power loss is 162 W, so the enclosure ventilation needs to handle that dissipation at the chosen derated current.

Panel integration — footprint and protection class

That depth (110 mm) is the dimension from the mounting surface to the front cover — critical for enclosure depth planning, especially if the panel has a shallow gland plate or a rear-mounted busbar system.

Ground-fault and communication — what the ETU860 adds

Communication function is present (yes), which means this breaker can report status and trip events over a bus system, though the exact protocol is not listed in this spec set. The undervoltage release is not fitted on this variant; if undervoltage protection is required, a different order code or an add-on module is needed.

Frequently asked questions

Where can I buy 3VA2463-0KQ32-0AA0 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at the time of quote — no stock count or price is published here.

What are the key ratings for 3VA2463-0KQ32-0AA0?

The breaker is rated for 630 A continuous at 40 °C, with a breaking capacity of 440 kA at 415 V and 187 kA at 690 V. The ETU860 electronic trip unit provides adjustable overcurrent protection and ground-fault monitoring.

What is the physical size of this MCCB?

The dimensions are 248 mm high, 138 mm wide, and 110 mm deep. The front face is rated IP40.

Does this breaker include undervoltage release or communication?

Communication function is present, but the undervoltage release is not fitted on this variant. Ground-fault monitoring uses summation current formation on the L-conductor.

MPN
3VA2463-0KQ32-0AA0