Skip to main content
Siemens 3VA2463-4HM42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-4HM42-0AA0 SENTRON MCCB, 630A, 4-Pole, Line

MPN3VA2463-4HM42-0AA0

Siemens SENTRON 3VA2463-4HM42-0AA0, Molded case circuit breaker, 4-pole, 630 A, line protection, adjustable thermal-magnetic trip 945-5670 A.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-4HM42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2463-4HM42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V52.5 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W
3VA2463-4HM42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2463-4HM42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-4HM42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2463-4HM42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-4HM42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.76 in
Width (in)7.24 in
Depth (in)4.33 in

Product details

630 A SENTRON MCCB for Line Protection

The adjustable thermal-magnetic trip unit spans 945 A minimum to 5 670 A maximum, giving you a wide coordination window for selective tripping downstream. Interrupting capacity is voltage-dependent: 121 kA at 240 V, 75.6 kA at 415 V and 440 V, 52.5 kA at 500 V, and 9 kA at 690 V. Thermal derating is published across the operating range: 630 A at 40 °C, dropping to 520 A at 70 °C. If your enclosure runs hot — say a non-ventilated panel near a furnace line — you need to size for the 70 °C figure, not the 40 °C nameplate.

Ground-Fault and Trip Details

This MCCB includes ground-fault monitoring via summation current formation on the L + N conductor — it measures the vector sum of phase and neutral currents to detect leakage to earth. The trip indicator is not fitted (no mechanical flag showing the breaker tripped on fault vs. manual off), and there is no undervoltage release or voltage trigger. Power loss at full rated current is 162 W maximum. In a dense panel with multiple breakers, that heat adds up — plan ventilation or spacing accordingly. Dimensions are 110 mm deep, 184 mm wide, 248 mm high (4.33 × 7.24 × 9.76 in), a standard 4-pole MCCB footprint that fits most Siemens switchboard mounting patterns.

Frequently asked questions

Does this breaker include ground-fault protection?

Yes, it has ground-fault monitoring via summation current formation on the L + N conductor — measures the vector sum of phase and neutral currents to detect earth leakage.

MPN
3VA2463-4HM42-0AA0