Siemens 3VA2463-5HL32-0DB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5HL32-0DB0 SENTRON MCCB, 630 A, 187 kA at 24

MPN3VA2463-5HL32-0DB0

Siemens SENTRON 3VA2463-5HL32-0DB0, 3-pole molded case circuit breaker, 630 A rated continuous current, ETU320 electronic trip unit, breaking capacity 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-5HL32-0DB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2463-5HL32-0DB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V55 kA
Breaking capacity at 500 V36 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W
3VA2463-5HL32-0DB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2463-5HL32-0DB0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-5HL32-0DB0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
3VA2463-5HL32-0DB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-5HL32-0DB0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.8 in
Width (in)5.4 in

Product details

The Siemens 3VA2463-5HL32-0DB0 is a SENTRON 3-pole molded case circuit breaker rated for 630 A continuous current at 40 °C, with an ETU320 electronic trip unit. The 187 kA breaking capacity at 240 V and 121 kA at 415 V give it the headroom to handle high-fault scenarios typical of main feeders or large distribution panels — the 690 V rating of 9 kA tells you this is a line-protection device, not a motor-protection breaker, so verify your load type before specifying.

Breaking capacity drops from 187 kA at 240 V to 121 kA at 415 V, then 55 kA at 440 V, 36 kA at 500 V, and 9 kA at 690 V — that steep curve means you size the SCCR for your actual line voltage, not the best-case number. Continuous current derates from 630 A at 40 °C to 520 A at 70 °C; at 70 °C ambient you lose roughly 17 % of the headline rating, so account for enclosure heat rise in the panel schedule.

Integration and form factor

The 3VA2463-5HL32-0DB0 measures 138 mm wide, 248 mm high, and 110 mm deep. IP40 on the front protects against tools and small wires.

Trip unit and adjustability

The ETU320 electronic trip unit offers adjustable long-time pickup (Ir) from 0.5 to 1.0 × Iu, with a configurable delay (tr) between 0.5 and 12 seconds. The 630 A maximum Ir setting matches the breaker's rated continuous current.

Frequently asked questions

Does the 3VA2463-5HL32-0DB0 include ground fault protection?

No, this is the version without ground fault monitoring — the standard line-protection variant with the ETU320 trip unit.

MPN
3VA2463-5HL32-0DB0