Skip to main content
Siemens 3VA2463-5HN32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5HN32-0AC0 SENTRON MCCB, 630 A, 187 kA

MPN3VA2463-5HN32-0AC0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2463-5HN32-0AC0, 630 A, 3-pole, ETU350 electronic trip unit, line protection, 187 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-5HN32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2463-5HN32-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.162 W
3VA2463-5HN32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2463-5HN32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-5HN32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2463-5HN32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-5HN32-0AC0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The Siemens 3VA2463-5HN32-0AC0 is a 3-pole SENTRON molded case circuit breaker rated for 630 A continuous current at 40 °C, with an ETU350 electronic trip unit handling line protection. At 415 V and 440 V it still holds 121 kA, and at 690 V it drops to 17 kA, so the voltage you're feeding matters for coordination studies. Thermal derating is built in: at 45 °C it carries 612 A, at 50 °C 593 A, stepping down to 520 A at 70 °C. If your enclosure runs hot, factor the curve — the 630 A nameplate is only valid at 40 °C ambient.

Integration and compliance notes

The 3VA2463-5HN32-0AC0 ships with 2 auxiliary switches (HQ type) pre-installed — no separate order for aux contacts on the first fit. The base switch supplied is 3VA2463-5HN32-0AA0, so the -0AC0 is the fully assembled catalog number with the aux contacts. Rated insulation voltage is 800 V, storage range -40 °C to 80 °C, operating range -25 °C to 70 °C.

Frequently asked questions

How do I get current pricing and availability for 3VA2463-5HN32-0AC0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time through independent distribution channels — no automated price or lead time is published here.

What is the closest functional alternative to 3VA2463-5HN32-0AC0?

The 3VA1112-5EF32-0CA0 is a smaller-frame SENTRON MCCB (lower amp rating, different trip unit). It will not drop into a panel wired for the 630 A 3VA2463 frame without busbar and lug changes — the physical footprint and termination differ. For a like-for-like swap, stay within the 3VA2 630 A frame family.

What compliance documentation is available for this MCCB?

As a Siemens SENTRON product, it carries IEC/EN 60947-2 certification. RoHS and REACH declarations are standard with the brand. Specific UL listing status should be confirmed against the exact catalog number at quote time.

MPN
3VA2463-5HN32-0AC0