Skip to main content
Siemens 3VA2463-5HN32-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5HN32-0CH0 SENTRON MCCB, 630 A, 3-Pole, 187

MPN3VA2463-5HN32-0CH0

Siemens SENTRON 3VA2463-5HN32-0CH0, molded case circuit breaker, 3-pole, 630 A, 187 kA at 240 V, line protection, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-5HN32-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2463-5HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2463-5HN32-0CH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C612 A
Current at 50 °C593 A
Current at 55 °C575 A
Current at 60 °C557 A
Current at 65 °C538 A
Current at 70 °C520 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.164.5 W
3VA2463-5HN32-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-5HN32-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-5HN32-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2463-5HN32-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-5HN32-0CH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA2463-5HN32-0CH0 is a SENTRON molded case circuit breaker (MCCB) rated for 630 A continuous at 40 °C, with a maximum breaking capacity of 187 kA at 240 V AC.

The 630 A continuous rating at 40 °C is the baseline — at elevated ambient temperatures the breaker derates linearly: 612 A at 45 °C, 593 A at 50 °C, down to 520 A at 70 °C. For a panel running at 50 °C ambient, the usable current drops to 593 A, so size the load accordingly. At 415 V the capacity is 121 kA, at 500 V it's 75.6 kA, and at 690 V it drops to 9 kA, so verify the system voltage against the curve.

Built-in accessories and integration

No communication module is included, so remote monitoring relies on hardwired I/O.

Deployment context

This breaker mounts in a standard panel or enclosure on a mounting plate — no DIN-rail clip, so plan for bolt-down installation. The 110 mm depth, 138 mm width, and 248 mm height fit typical MCCB cutouts; verify panel door clearance for the handle and auxiliary wiring.

Frequently asked questions

Who supplies 3VA2463-5HN32-0CH0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the breaking capacity of 3VA2463-5HN32-0CH0 at different voltages?

At 240 V it is 187 kA, at 415 V and 440 V it is 121 kA, at 500 V it is 75.6 kA, and at 690 V it is 9 kA.

What accessories come with this MCCB?

It includes an undervoltage release and a set of two auxiliary switches plus one trip alarm switch (HQ configuration).

MPN
3VA2463-5HN32-0CH0