Siemens 3VA2463-5HN32-0HG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5HN32-0HG0 630A Circuit Breaker, 55kA @ 415V

MPN3VA2463-5HN32-0HG0

Siemens 3VA2 series, IEC frame 630 MCCB, breaking capacity class M, Icu=55kA @ 415V, 3-pole, ETU350 LSI trip unit, In=630A, shunt trip left 24V AC/DC, 1 auxiliary switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

The Siemens 3VA2463-5HN32-0HG0 is an IEC frame 630 molded case circuit breaker from the 3VA2 series, rated for 55 kA interrupting capacity at 415 V (class M). It is fitted with an ETU350 LSI electronic trip unit, set for a nominal current In of 630 A, with overload protection Ir adjustable from 250 A to 630 A and short-circuit protection Isd adjustable from 1.5 to 9 times Ir. The instantaneous pickup Ii is fixed at 9 times In. The breaker includes a factory-installed shunt trip on the left side, rated for 24 V AC 50/60 Hz or 24–30 V DC, and provisions for one auxiliary switch.

Key Ratings and Fit

The 55 kA Icu at 415 V places this breaker in the M (medium) breaking capacity class, suitable for industrial distribution panels where fault currents are moderate but still require robust interruption — typical for secondary switchgear or large motor control center feeders. The ETU350 LSI trip unit provides adjustable long-time (Ir), short-time (Isd), and instantaneous (Ii) protection, allowing coordination with downstream devices. The 630 A frame and adjustable Ir range (250–630 A) mean it can be downsized to protect a feeder as low as 250 A without changing the breaker frame.

Integrated Accessories

The shunt trip on the left side operates on 24 V AC or 24–30 V DC, enabling remote tripping from a safety circuit or emergency-stop system. The provision for one auxiliary switch allows status feedback (open/closed) to a PLC or indication panel. These accessories are factory-installed, reducing field wiring and panel-build labor.

Frequently asked questions

What is the interrupting rating of this breaker?

The ultimate breaking capacity Icu is 55 kA at 415 V AC, which is the class M rating for the 3VA2 IEC frame 630.

What trip unit does this breaker use?

It uses an ETU350 LSI electronic trip unit with adjustable long-time (Ir 250–630 A), short-time (Isd 1.5–9× Ir), and fixed instantaneous (Ii 9× In) protection.

What voltage does the shunt trip require?

The shunt trip is rated for 24 V AC 50/60 Hz or 24–30 V DC, factory-installed on the left side.

Where can I buy 3VA2463-5HN32-0HG0 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.