Siemens 3VA2463-5HN32-0KF0 Circuit Breaker, 630A, 55kA @ 415

MPN3VA2463-5HN32-0KF0

Siemens 3VA2 IEC frame 630 circuit breaker, breaking capacity class M, Icu=55kA @ 415V, 3-pole, line protection ETU350, LSI, In=630A, overload protection Ir=250A...630A, shunt trip left 208-277V AC 50/60Hz 220-250V DC, 1 auxiliary switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

What this breaker carries — and what that means for your panel

The Siemens 3VA2463-5HN32-0KF0 is a 3-pole IEC frame 630 molded-case circuit breaker rated for 630 A continuous current with an Icu of 55 kA at 415 V AC — that's the maximum fault current it can safely interrupt without damage under IEC 60947-2. The ETU350 electronic trip unit gives you LSI protection: long-time (Ir adjustable 250–630 A), short-time (Isd 1.5–9× Ir), and instantaneous (Ii fixed at 9× In). That adjustable Ir range means you size the breaker to the actual load, not the frame; set Ir to match the downstream conductor ampacity.

Built-in accessories save a panel-build step

This order code ships with a shunt trip fitted on the left side, rated 208–277 V AC 50/60 Hz and 220–250 V DC, plus one auxiliary switch. The auxiliary switch signals breaker position (open/closed) back to a PLC or status lamp. Both are factory-installed, so they land on the DIN rail as a single unit.

Frequently asked questions

Where can I buy 3VA2463-5HN32-0KF0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of this breaker?

The Icu (ultimate breaking capacity) is 55 kA at 415 V AC, which is the class M rating on the 3VA2 IEC frame 630. That means it can safely interrupt fault currents up to 55 kA once under IEC 60947-2.

What trip unit and protection functions does this breaker have?

It uses an ETU350 electronic trip unit with LSI protection: long-time (Ir adjustable 250–630 A), short-time (Isd adjustable 1.5–9× Ir), and instantaneous (Ii fixed at 9× In). The adjustable Ir lets you match the breaker to the actual load current.