Skip to main content
Siemens 3VA2463-5HN42-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5HN42-0DL0 Circuit Breaker, 630A, 55kA @ 415

MPN3VA2463-5HN42-0DL0

Siemens 3VA2 IEC frame 630, breaking capacity class M, 55kA @ 415V, 4-pole, ETU350 LSI, In=630A, undervoltage release 208-230V AC, auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2463-5HN42-0DL0 is a 4-pole IEC frame 630 circuit breaker with a 55 kA breaking capacity at 415 V (class M). It uses an ETU350 trip unit configured for LSI protection — long-time (Ir adjustable 250–630 A), short-time (Isd 1.5–9× Ir), and instantaneous (Ii fixed at 9× In). The neutral conductor protection is adjustable: OFF, 50%, or 100% of phase current. This is a line-protection build — it's meant for main or feeder duty in a distribution panel, not motor branch circuit protection.

The 55 kA Icu at 415 V places this in breaking capacity class M — it's sized for high-fault installations where upstream transformers or large motor groups can deliver substantial short-circuit current. The 630 A frame (In) with Ir adjustable down to 250 A means you can cable this for a 630 A bus but set the overload pickup to match a smaller downstream load, preserving selectivity headroom. The undervoltage release (208–230 V AC) drops the breaker if control voltage is lost — common in emergency-stop chains or mains-loss schemes. Verify the release coil voltage matches your control transformer before panel wiring.

Frequently asked questions

Where can I buy 3VA2463-5HN42-0DL0 and get a price?

This part is sourced and quoted to order against an RFQ through independent industrial distribution. Submit an RFQ for current availability and pricing — no stock count or price is published here.

What does the 55 kA breaking capacity at 415 V mean for my panel?

The 55 kA Icu at 415 V is the maximum short-circuit current the breaker can safely interrupt under fault conditions. For a 400 V distribution board fed by a transformer of 2000 kVA or larger, this rating provides adequate fault-clearing capability without cascading upstream. It's class M — mid-range in the 3VA2 family between standard (S) and high (H) breaking capacities.

MPN
3VA2463-5HN42-0DL0