Skip to main content
Siemens 3VA2463-5HR32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5HR32-0AA0 Circuit Breaker, 630A, 55kA @ 415

MPN3VA2463-5HR32-0AA0

Siemens 3VA2 IEC frame 630, breaking capacity class M, Icu=55kA @ 415 V, 3-pole, line protection ETU345, LI DTVE, In=630A without overload protection, Ir=252A...630A, Ii=9 x In, busbar connection.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2463-5HR32-0AA0 is a 3-pole IEC frame 630 molded-case circuit breaker with a 55 kA interrupting capacity at 415 V (class M). It carries an ETU345 LI electronic trip unit configured for line protection — the LI curve means long-time and instantaneous protection, no short-time delay. Rated continuous current In is 630 A, but the overload protection (Ir) is adjustable from 252 A to 630 A, and the instantaneous pickup Ii is fixed at 9 × In (5670 A). This is a busbar-connected unit, so it lands directly on a panel bus, not a line-side cable.

The ETU345 LI trip unit is electronic, so it offers better accuracy and adjustability than a thermal-magnetic breaker; the Ir adjustment range (252–630 A) lets you match the breaker to the actual load without changing the frame. The lack of overload protection (the description flags 'without overload protection') means this unit is intended for use where the overload function is handled elsewhere — typically a separate overload relay for motor circuits, or a downstream feeder breaker. The instantaneous pickup at 9 × In is a fixed value, so coordination studies should account for that threshold.

Deployment Context

This breaker mounts in a switchboard or panel via the busbar connection — no DIN-rail adapter, it bolts directly to the bus. The 3VA2 frame is the 630 A frame size; panel cutouts and bus spacing follow the standard 3VA2 footprint. For an OEM panel builder, the busbar connection saves wiring time on the main feed, but verify the busbar center-to-center spacing matches your panel layout.

Frequently asked questions

What is the breaking capacity of 3VA2463-5HR32-0AA0?

Icu is 55 kA at 415 V AC, which is the class M breaking capacity per IEC 60947-2.

Where can I buy 3VA2463-5HR32-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2463-5HR32-0AA0