Skip to main content
Siemens 3VA2463-5JP32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2463-5JP32-0AH0 MCCB, 630 A, ETU550, 187

MPN3VA2463-5JP32-0AH0

Siemens SENTRON 3VA2463-5JP32-0AH0 molded case circuit breaker, 3-pole, 630 A rated continuous current, ETU550 electronic trip unit, line protection version, breaking capacity 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, 17 kA at 690 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2463-5JP32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-5JP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2463-5JP32-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C600 A
Current at 50 °C570 A
Current at 55 °C540 A
Current at 60 °C510 A
Current at 65 °C480 A
Current at 70 °C450 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.162 W
3VA2463-5JP32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
3VA2463-5JP32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-5JP32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2463-5JP32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-5JP32-0AH0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The Siemens SENTRON 3VA2463-5JP32-0AH0 is a 3-pole molded case circuit breaker rated for 630 A continuous current at 40 °C, with an ETU550 electronic trip unit. The breaking capacity tells you the fault current it can safely interrupt: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. These are the numbers that govern whether this breaker holds under a short-circuit condition at your service voltage — if your available fault current exceeds the rating at your voltage, you need a different frame or upstream current-limiting device. That means you can coordinate this breaker downstream of a main or upstream of branch feeders without guessing — the trip curve is programmable, not fixed like a thermal-magnetic unit. The breaker also includes a communication function, so it can report status and trip events to a monitoring system. That depth includes the case body — check clearance for the rear terminals and any accessory modules (auxiliary switches or shunt trip) that add projection.

For procurement: this is a stocked, active Siemens SENTRON line item. Submit an RFQ with your quantity and target delivery window; we'll return a firm commercial offer.

What's inside — the ETU550 trip unit

The ETU550 is the electronic brain of this breaker. It provides adjustable protection parameters via a local interface or remotely through the communication module. No undervoltage release or shunt trip is included from the factory, but those can be added as field-installable accessories if your safety circuit requires a UVR to drop the breaker on power loss. The trip indicator gives a visual flag after a fault trip — helps a technician identify which breaker opened without needing to interrogate the trip unit. Temperature derating is already factored into the continuous current ratings: 630 A at 40 °C, stepping down to 450 A at 70 °C.

Frequently asked questions

Where can I buy 3VA2463-5JP32-0AH0 and how do I get a price?

This part is sourced through our independent distribution channel. Submit an RFQ with your quantity and target delivery date; we will confirm availability and current pricing at quote time.

What is the breaking capacity of this MCCB at different voltages?

The breaking capacity is 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 17 kA at 690 V. These are the maximum fault currents the breaker can safely interrupt at each voltage level.

What are the physical dimensions of 3VA2463-5JP32-0AH0?

The breaker measures 248 mm high, 138 mm wide, and 110 mm deep. The depth is the case body only — allow extra clearance for rear terminals and any accessory modules.

What trip unit does this breaker use?

It uses the ETU550 electronic trip unit, which provides adjustable long-time, short-time, instantaneous, and ground-fault protection curves. It also includes a communication function for remote monitoring.

MPN
3VA2463-5JP32-0AH0