Skip to main content
Siemens 3VA2463-5JP32-0DA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5JP32-0DA0 SENTRON MCCB, 630 A, 3-Pole, ETU5

MPN3VA2463-5JP32-0DA0

Siemens SENTRON 3VA2463-5JP32-0DA0, molded case circuit breaker, 3-pole, line protection, rated current 630 A, ETU550 electronic trip unit, breaking capacity 187 kA at 240 V AC, 121 kA at 415 V AC, with undervoltage release and communication function, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-5JP32-0DA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2463-5JP32-0AA0
3VA2463-5JP32-0DA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C630 A
Current at 45 °C600 A
Current at 50 °C570 A
Current at 55 °C540 A
Current at 60 °C510 A
Current at 65 °C480 A
Current at 70 °C450 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.164.5 W
3VA2463-5JP32-0DA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2463-5JP32-0DA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-5JP32-0DA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2463-5JP32-0DA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-5JP32-0DA0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

MCCB for high-current line protection

The Siemens SENTRON 3VA2463-5JP32-0DA0 is a 3-pole molded case circuit breaker rated at 630 A continuous current at 40 °C, with an ETU550 electronic trip unit for adjustable protection curves.

The continuous current rating is temperature-dependent: 630 A at 40 °C, derating to 600 A at 45 °C, 570 A at 50 °C, 540 A at 55 °C, 510 A at 60 °C, 480 A at 65 °C, and 450 A at 70 °C. Maximum power loss is 164.5 W. For a panel OEM, this means the breaker needs adequate ventilation or forced cooling if ambient in the enclosure exceeds 40 °C — the derating curve is the real-world limit, not the 630 A nameplate.

Breaking capacity varies with system voltage: 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V. For most 400 V industrial networks, the 121 kA rating covers high-fault scenarios.

Physical integration and environment

Dimensions: 248 mm height, 138 mm width, 110 mm depth. Front protection class IP40. Includes undervoltage release and communication function. Rated insulation voltage 800 V.

Frequently asked questions

What is the depth of 3VA2463-5JP32-0DA0?

The depth is 110 mm (4.33 in).

What is the width of 3VA2463-5JP32-0DA0?

The width is 138 mm (5.43 in).

MPN
3VA2463-5JP32-0DA0