Skip to main content
Siemens 3VA2463-5JP32-0KG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5JP32-0KG0 SENTRON MCCB, 630 A, 187 kA

MPN3VA2463-5JP32-0KG0

Siemens SENTRON 3VA2463-5JP32-0KG0, molded case circuit breaker, 3-pole, 630 A at 40 °C, 187 kA at 240 V, ETU550 electronic trip unit, shunt trip, auxiliary switch.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2463-5JP32-0KG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2463-5JP32-0KG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C600 A
Current at 50 °C570 A
Current at 55 °C540 A
Current at 60 °C510 A
Current at 65 °C480 A
Current at 70 °C450 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W
3VA2463-5JP32-0KG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2463-5JP32-0KG0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2463-5JP32-0KG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2463-5JP32-0KG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2463-5JP32-0KG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

The Siemens 3VA2463-5JP32-0KG0 is a SENTRON molded case circuit breaker rated 630 A at 40 °C ambient, with a maximum breaking capacity of 187 kA at 240 V AC. At 415 V and 440 V it still holds 121 kA, and at 690 V it drops to 9 kA, so the voltage-dependent curve is what governs your SCCR coordination study. Ambient operating range is -25 °C to 70 °C, with current derating starting at 40 °C — at 50 °C it's 570 A, at 60 °C it's 510 A, and at 70 °C it's 450 A.

The 110 mm depth leaves room for rear-connection busbars or cable lugs in a typical 600 mm deep enclosure.

Frequently asked questions

What is the adjustable current range on the ETU550 trip unit?

The ETU550 allows adjustment from a minimum of 126 A up to a maximum of 1 008 A. This covers a broad range of load sizing without changing the breaker frame.

Does this breaker include a shunt trip and auxiliary contacts?

Yes, it comes with a shunt trip release (STL) for remote tripping, plus one auxiliary switch and one trip alarm switch HP for status feedback.

MPN
3VA2463-5JP32-0KG0