Siemens 3VA2463-5KP32-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2463-5KP32-0AC0 SENTRON MCCB, 630 A, 3-Pole, 187

MPN3VA2463-5KP32-0AC0

Siemens SENTRON 3VA2463-5KP32-0AC0, molded case circuit breaker, 3-pole, 630 A continuous at 40 °C, interrupting capacity 187 kA at 240 V AC, 121 kA at 415 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2463-5KP32-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2463-5KP32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2463-5KP32-0AC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C630 A
Current at 45 °C600 A
Current at 50 °C570 A
Current at 55 °C540 A
Current at 60 °C510 A
Current at 65 °C480 A
Current at 70 °C450 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V9 kA
Power loss, max.162 W

Protection & Trip Unit

3VA2463-5KP32-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2463-5KP32-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2463-5KP32-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2463-5KP32-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2463-5KP32-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height248 mm
Width138 mm
Depth110 mm
Height (in)9.76 in
Width (in)5.43 in
Depth (in)4.33 in

Product details

Siemens SENTRON 3VA2463-5KP32-0AC0 — 630 A Molded Case Circuit Breaker, 3-Pole, Line Protection

The Siemens SENTRON 3VA2463-5KP32-0AC0 is a 3-pole molded case circuit breaker (MCCB) rated for 630 A continuous current at 40 °C, designed for line protection in industrial power distribution. Its interrupting capacity reaches 187 kA at 240 V AC and 121 kA at 415 V AC, providing robust fault-clearing capability for high-fault-current panels. The breaker includes a communication function for integration into networked power monitoring systems.

Rating and Derating — Continuous Current vs. Ambient Temperature

The 630 A rating is at 40 °C ambient. For higher ambient temperatures, the continuous current must be derated per the datasheet curve: 600 A at 45 °C, 570 A at 50 °C, 540 A at 55 °C, 510 A at 60 °C, 480 A at 65 °C, and 450 A at 70 °C. This derating is critical for panel design in non-air-conditioned enclosures or high-heat environments.

Interrupting Capacity Across Voltage Levels

The breaker's interrupting capacity varies with system voltage: 187 kA at 240 V, 121 kA at both 415 V and 440 V, 75.6 kA at 500 V, and 9 kA at 690 V. For audit purposes, the 121 kA rating at 415 V is the figure most commonly referenced in European low-voltage distribution designs per IEC 60947-2.

Physical Dimensions and Panel Fit

The breaker measures 248 mm in height, 138 mm in width, and 110 mm in depth. The 110 mm depth is a key dimension for enclosure depth clearance — verify that the panel door or gland plate allows at least this depth plus wiring bend radius for the line and load conductors.

Frequently asked questions

Where can I buy 3VA2463-5KP32-0AC0 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current pricing and availability confirmation.

What is 3VA2463-5KP32-0AC0's listed depth?

The listed depth is 110 mm, which is the dimension from the mounting surface to the front of the breaker.

What compliance documentation does this brand provide for 3VA2463-5KP32-0AC0?

As a SENTRON series MCCB, the 3VA2463-5KP32-0AC0 is designed to meet IEC 60947-2 and UL 489 standards. The manufacturer provides RoHS and REACH declarations on request.

MPN