Siemens 3VA2463-5KP32-0AL0 630A Circuit Breaker, 55kA @ 415V

MPN3VA2463-5KP32-0AL0

Siemens 3VA2 IEC frame 630, 3-pole, breaking capacity class M, Icu=55kA @ 415V, ETU850 LSI trip unit, In=630A, Ir adjustable 250-630A, Isd=0.6-9x In, Ii=1.5-9x In, 2 auxiliary changeover switches + 1 trip alarm changeover.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Product details

The Siemens 3VA2463-5KP32-0AL0 is a 630A IEC frame circuit breaker from the 3VA2 series, rated at 55kA Icu at 415V AC — Breaking Capacity Class M. The ETU850 trip unit gives you LSI protection: Long-time pickup Ir adjustable 250A through 630A, short-time pickup Isd from 0.6x to 9x In, and instantaneous Ii from 1.5x to 9x In. That range covers motor-start inrush and transformer magnetizing peaks without nuisance tripping — set the Isd delay to coordinate with downstream breakers.

Line-down fit and auxiliaries

This unit ships with two auxiliary changeover switches and one trip alarm changeover switch pre-installed — no separate order for alarm contacts. Neutral conductor protection is optional via an external current transformer, up to 160% of In. Mounts on the standard DIN rail or bolted into the switchboard. The 3VA2 frame footprint matches existing 3VA1 cutouts in most Siemens panels — verify gland plate clearance if retrofitting into a legacy cubicle.

Frequently asked questions

What does the 55kA Icu rating mean for my panel coordination?

55kA Icu at 415V means this breaker can safely clear a 55kA prospective short-circuit current. That's enough for most industrial main feeders — you can coordinate downstream breakers rated lower (say 25kA or 36kA) as long as the let-through energy stays within their ratings.

What auxiliary contacts come on this breaker?

It ships with two auxiliary changeover switches and one trip alarm changeover switch — all pre-installed. No separate order for alarm signaling.

Where can I buy 3VA2463-5KP32-0AL0?

This part is sourced and quoted to order against an RFQ through our independent distribution channel. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN